TS25 MKII : TS25-BAS1-KIT : TS25-BAS1-CAN-240
Battery charger/analyser : Operators Manual
The TS25 MKII contains the ability that will allow it to be calibrated by the end user. The
equipment needed is a good 24V battery, an ammeter capable of reading up to 25A (or a
shunt and milli-voltmeter combination) and a voltmeter capable of reading up to 30V. The
re-calibration process only takes a few minutes and this is done without the need to access
the interior of the TS25 MKII.
The TS25 MKII no longer supports deep discharge recovery mode. It is thought that if a
battery requires this level of charge to "recover" it then the battery is not fit for use anyway
and should be disposed of for re-cycling.
The TS25 MKII contains two hi flow rate fans to extract the heat energy generated internally
when running in capacity test mode.
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt
Page 6 of 46
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17