TS25 MKII : TS25-BAS1-KIT : TS25-BAS1-CAN-240
Battery charger/analyser : Operators Manual
6 ROUTINE MAINTENANCE
Your TS25 MKII is designed to give you many years of trouble free use and Intelligent
Charging recommends that at least once per year the following routine maintenance checks
should be followed.
•
Perform a calibration check as covered in the CALIBRATION section.
•
Ensure that the cooling fans can run freely and are not clogged with dust and dirt.
•
Ensure that all the inlet vents are free from obstructions and if necessary clear any
obstructions.
•
Inspect the battery leads to ensure that the connections are still sound and there is no
evidence of fraying of cable strands at the connectors and no build up of corrosion due
to battery acid or alkaline. If the connectors are broken or damaged they should be
replaced. Replacement charger connectors can be purchased from Intelligent Charging.
•
Inspect the power cord for damage and replace if necessary.
•
If required by local regulations perform a PAT test on the equipment in accordance with
the regulations in force.
6.1 INTERNAL BATTERY REPLACEMENT
The internal parameters of the TS25 MKII are maintained by a single coin cell
mounted on the display PCB at the front of the unit. This should be changed every 5-6
years. If it should fail during use the error code
E13
will be displayed when power is
applied to the unit.
The cell is a standard Lithium button cell number CR2024. When replacing
the battery please observe the correct methods of disposal of the old
battery in accordance with your local regulations.
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt
Page 31 of 46
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17