4.4 ENTERING BATTERY DATA
In all cases of entering battery data the channel that data is to be entered on must be
in the stopped state. This is indicated by the
END
lamps being illuminated.
4.4.1 SETTING CAPACITY TEST MODE
Press
PROC
the display will flash the current mode on the display. Using the
and
arrow keys the flashing display can be changed from
TIM
to
VOL
and visa
versa. Once selection has been made the
ENTR
key will be pressed to program
this parameter into the unit. If no change is required then simply pressing
STOP
will clear the display.
TIM
Programs the capacity testing mode to auto terminate when the battery
voltage falls below the voltage end point or when the time up has been
reached.
VOL
Programs the capacity testing mode to only auto terminate when the
voltage end point has been reached.
4.4.2 SETTING THE CHARGE MODE
Press
PROC
the display will flash the current mode on the display. Using the
and
arrow keys the flashing display can be changed from
CV
,
CC
and
CCA
and
visa versa. Once selection has been made the
ENTR
key will be pressed to
program this parameter into the unit. If no change is required then simply
pressing
STOP
will clear the display.
CV
Programs the charge mode to perform a constant voltage charge where the
charge current is not exceeded until the voltage set point is reached at
which point it reduces current to maintain the voltage set point until the
charge time is completed.
CC
Programs the charge mode to perform constant current charging for the
time specified terminating abnormally if the voltage set point is reached.
CCA
Programs the charge mode to perform constant current charging until the
voltage set point is reached and then continue charging at the same current
until the additional time has elapsed.
4.4.3 ENTERING CURRENT DATA
Press the
ASET
key. The current setting will be displayed. The rightmost digit will
be flashing and can be modified by pressing the
and
arrow keys. Pressing
the EXTD key will cause the middle digit to flash and this can then be modified by
using the
and
arrow keys. Pressing the EXTD key again will cause the
leftmost digit to flash and this can then be modified using the
and
arrow
keys. If the EXTD key is pressed again the rightmost digit will then flash. This
cycle is repeated each time the EXTD key is pressed. The values cannot be
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt
Page 20 of 46
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17