TS25 MKII : TS25-BAS1-KIT : TS25-BAS1-CAN-240
Battery charger/analyser : Operators Manual
•
The charger display will then adjust the display to show the same reading as
the measuring equipment.
•
Once the process is completed press
STOP
to end the charge.
•
Charge circuit calibration is complete.
•
If necessary the same process is performed for channel B.
5.3.2 Capacity Test Re-Calibration.
Connect the measuring equipment in accordance with the calibration equipment
connection diagram to Channel A.
•
Set the battery charger to test mode.
•
Set capacity test amps to 25A using the
ASET
key.
•
Set the termination voltage to 20V using the
VSET
key.
•
Set the capacity test duration to
010
using the
TSET
key.
•
Press
START
to begin the capacity test process.
•
Allow the capacity test current to stabilise.
•
Press the
ENTR
key rapidly twice
•
The display will briefly display
CAL
.
•
To re-calibrate current press
ASET
.
•
Enter the number of amps displayed on the measuring equipment, then press
ENTR
.
•
The charger will adjust the charge amps so that the measuring equipment will
then display the same as the charger.
•
To recalibrate voltage press
VSET
•
Enter the number of volts as displayed on the measuring equipment and press
ENTR
.
•
The charger display will then adjust the display to show the same reading as
the measuring equipment.
•
Once this process is completed press
STOP
to end the capacity test.
•
Capacity test circuit calibration is complete.
•
If necessary the same process is performed for channel B.
5.4 CALIBRATION PROBLEMS
The TS25 MKII has in-built protection to prevent erroneous calibration data from being
entered.
When performing a re-calibration the unit will validate the data to ensure that it is
within reasonable boundaries. If when entering measurements into the unit it beeps
and displays
E 6
then the volts or amps you are trying to enter are invalid.
If the same error is displayed on repeat attempts it is an indication of a breakdown in
the internal circuitry and the unit will need to be quarantined and returned to
Intelligent Charging for service.
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt
Page 29 of 46
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17