TS25 MKII : TS25-BAS1-KIT : TS25-BAS1-CAN-240
Battery charger/analyser : Operators Manual
modified to greater than 12.0A for charge mode and 25.0A for capacity test
mode.
Note: In
ONE
mode the maximum values that can be entered are 24.0A for
charge mode and 50.0A for capacity test mode.
4.4.4 ENTERING VOLTAGE DATA
Press the
VSET
key. The current setting will be displayed. The rightmost digit will
be flashing and can be modified by pressing the
and
arrow keys. Pressing
the EXTD key will cause the middle digit to flash and this can then be modified by
using the
and
arrow keys. Pressing the EXTD key again will cause the
leftmost digit to flash and this can then be modified using the
and
arrow
keys. If the EXTD key is pressed again the rightmost digit will then flash. This
cycle is repeated each time the EXTD key is pressed. The voltage value to be
entered cannot exceed 45.0V and the display will not allow digits to be
incremented above this amount.
4.4.5 ENTERING CAPACITY TEST TIME
Press the
TSET
key. The current setting will be displayed. The rightmost digit will
be flashing and can be modified by pressing the
and
arrow keys. Pressing
the EXTD key will cause the middle digit to flash and this can then be modified by
using the
and
arrow keys. Pressing the EXTD key again will cause the
leftmost digit to flash and this can then be modified using the
and
arrow
keys. If the EXTD key is pressed again the rightmost digit will then flash. This
cycle is repeated each time the EXTD key is pressed. The value entered is in
minutes and the maximum time that can be entered is 999 minutes.
4.4.6 ENTERING CHARGE TIME
Press the
VSET
key. The current setting will be displayed. The rightmost digit will
be flashing and can be modified by pressing the
and
arrow keys. Pressing
the EXTD key will cause the middle digit to flash and this can then be modified by
using the
and
arrow keys. Pressing the EXTD key again will cause the
leftmost digit to flash and this can then be modified using the
and
arrow
keys. If the EXTD key is pressed again the rightmost digit will then flash. This
cycle is repeated each time the EXTD key is pressed. The value entered is in
hours and the maximum time than can be entered in 99.9H.
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt
Page 21 of 46
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17