![Intelligent Charging TS25 MKII Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/intelligent-charging/ts25-mkii/ts25-mkii_operators-manual_2073972022.webp)
TS25 MKII : TS25-BAS1-KIT : TS25-BAS1-CAN-240
Battery charger/analyser : Operators Manual
4.5 USING THE ONE MODE OF OPERATION
The TS25MKII has a special feature in that if higher currents for charging or capacity
testing are required the unit can be "paralleled". Using special paired cables, which
connect, channel A and channel B together both channels can be used in unison.
WARNING
PAY CAREFUL ATTENTION TO BATTERY CONNECTION
WHEN USING “ONE” MODE
Control of the unit is all achieved through the use of the channel A keypad and the
channel B keypad only mimics some of the channel A functions. The channel B display
will change to an alternative display to channel A when the
DISP
key is pressed.
All operation of the equipment is the same as when using an individual channel, with
the exception that higher currents can be entered for capacity testing and charging.
If a library item has been written in one mode, it will only be recalled in ONE mode if
the current exceeds the single channel limitations of the unit.
Certain actions cannot be performed in ONE mode and these are reported on the
display in the form of an error message and buzzer sound.
4.6 RESETTING THE TS25 MKII
The TS25 MKII keeps users modified data in battery backed RAM. It may be necessary
at some time to reset this data to the defaults. Three sets of data can be reset.
4.6.1 GENERAL PARAMETER DATA
The general parameter data covers the current battery data that is set and
indicators to general unit operation. It is not usually necessary to reset this data
as is checked internally for correctness, but when the unit has been serviced and
the battery backup removed the general parameter data can be come corrupt
and may need resetting through the use of this function.
4.6.2 DEFAULT LIBRARY DATA
The operator may want at some time to reset the internal data library back to
the default battery library, this function copies the internal library into the user
definable battery library. Warning: The use of this function will remove all user
defined library items.
4.6.3 CALIBRATION PARAMETERS
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt
Page 22 of 46
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17