Intel® Server System M20NTP1UR - System Integration and Service Guide
68
6.8
OCP* Module Replacement
This section provides instructions for OCP* module replacement.
Required Tools and Supplies
•
OCP* Mezzanine Ethernet Network Adapter
•
OCP* module mounting screws – 4x screws included with the system
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver
1.
Power off the system and disconnect all cables from the back of the system.
2.
Remove the system top cover (see
Section 6.1.1
3.
Remove the Air Duct (see
Section 6.2.1
4.
Remove the riser card assembly (see
5.
Extract the OCP* Module from the system (See
Figure 82. OCP* Module Removal
•
Remove the four screws securing the OCP* module to the server board (see Letter “A”).
•
Carefully lift the back edge of the OCP* module until the connectors are free (see Letter “B”).
•
Gently pull the OCP* module away from the system back panel
Note
: If the OCP* module is not being replaced, then the OCP* module mounting bracket, attached to the
system back panel must be replaced with the original OCP* bay cover plate to ensure the system remains
compliant to EMI/EMC regulatory certifications.
Содержание M20NTP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Страница 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Страница 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Страница 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Страница 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...