Intel® Server System M20NTP1UR - System Integration and Service Guide
41
3.8
Ethernet Network Adapter for OCP* – Installation
This section provides instructions for OCP* adapter installation. Refer to the
Intel® Server M20NTP Family
Configuration Guide
for available options.
Required Tools and Supplies
•
OCP* Mezzanine Ethernet Network Adapter
•
OCP* module Mounting Bracket – Included with system
•
OCP* module mounting screws – 4x screws included with the system
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
Section 3.1.1
).
3.
Remove the Air Duct (see
Section 3.2.1
4.
Remove the riser card assembly (see
5.
Remove the OCP* bay cover plate from the system back panel (See
Caution:
If the OCP* module is removed and the bay becomes empty again, the OCP* bay cover plate must
be re-installed to ensure EMI/EMC regulatory compliance.
Figure 41. OCP* Adapter Bay Filler Removal
•
Remove the fastener screw from the right side of the cover plate (see Letter “A”).
•
Pull the cover plate away from the system (see Letter “B”).
6.
Locate and mount the OCP* module mounting bracket to the system back panel (See
Figure 42. OCP* Mounting Bracket Installation
Содержание M20NTP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Страница 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Страница 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Страница 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Страница 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...