Intel® Server System M20NTP1UR - System Integration and Service Guide
79
Each component within the PHM assembly includes a Pin 1 indicator. Pin 1 indicator alignment between all
components is required throughout the assembly process.
11.
Orient and align the processor carrier clip over the processor (See
Figure 100. Installing Processor Carrier Clip onto Processor – Part 1
•
With the processor still in its tray, place the processor carrier clip over the processor.
•
Ensure the Pin 1 indicator on the processor carrier clip is aligned with the Pin 1 indicator of
the processor.
12.
Place the carrier clip onto the processor
Figure 101. Installing Processor Carrier Clip onto Processor – Part 2
•
Gently press down simultaneously on two opposite sides of the processor carrier clip until it
clicks in place. Repeat for the other two sides.