Intel® Server System M20NTP1UR - System Integration and Service Guide
6
Weight of the system:
•
Due to the weight of a system, Intel recommends carrying the system with two people supporting the
system from the sides or using a mechanical lift or a cart when moving the system from one location
to another.
•
If your system has rack handles installed, do not lift or carry the system by the rack handles
•
When lifting or moving a chassis, always grasp it by all four corners. Do not grasp the chassis by two
points at opposing diagonal corners, doing so may damage the internal components.
•
If you can only grasp the chassis at two different points, always grasp the chassis by the sides at the
midpoint.
Installing or removing jumpers:
A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small
tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do
not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow
sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts
inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to
grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the
pins on the board.
Additional Cautions:
•
Slide / Rail mounted equipment is not to be used as a shelf or a workspace
•
Intel warranties that this product will perform to its published specifications. However, all computer
systems are inherently subject to unpredictable system behavior under various environmental and
other conditions.
•
This product is not intended to be the sole source for any critical data and the user must maintain a
verified backup. Failure to do so or to comply with other user notices in the product user guide and
specification documents may result in loss of or access to data.
Содержание M20NTP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Страница 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Страница 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Страница 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Страница 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...