1.
Locate the processor heat sink. To avoid damage, grasp it by its narrower sides as shown in
Figure 11. Processor Heat Sink Handling
2.
Place the heat sink bottom side up onto a flat surface.
3.
Remove the plastic protective film (if present) from the Thermal Interface Material (TIM).
4.
Place the heat sink Top side up onto a flat surface.
5.
Attach the heat sink to the processor assembly
Figure 12. Processor Heat Sink Anti-tilt Wires in the Outward Position
•
Set the anti-tilt wire over each of the four heat sink fasteners to their outward position.
Figure 13. Pin 1 Indicator of Processor Carrier Clip