THIRD PARTY OPTIC MODULES AND CABLES REFERRED TO ABOVE ARE LISTED ONLY FOR THE PURPOSE OF HIGHLIGHTING THIRD
PARTY SPECIFICATIONS AND POTENTIAL COMPATIBILITY, AND ARE NOT RECOMMENDATIONS OR ENDORSEMENT OR
SPONSORSHIP OF ANY THIRD PARTY’S PRODUCT BY INTEL. INTEL IS NOT ENDORSING OR PROMOTING PRODUCTS MADE BY ANY
THIRD PARTY AND THE THIRD PARTY REFERENCE IS PROVIDED ONLY TO SHARE INFORMATION REGARDING CERTAIN OPTIC
MODULES AND CABLES WITH THE ABOVE SPECIFICATIONS. THERE MAY BE OTHER MANUFACTURERS OR SUPPLIERS, PRODUCING
OR SUPPLYING OPTIC MODULES AND CABLES WITH SIMILAR OR MATCHING DESCRIPTIONS. CUSTOMERS MUST USE THEIR OWN
DISCRETION AND DILIGENCE TO PURCHASE OPTIC MODULES AND CABLES FROM ANY THIRD PARTY OF THEIR CHOICE.
CUSTOMERS ARE SOLELY RESPONSIBLE FOR ASSESSING THE SUITABILITY OF THE PRODUCT AND/OR DEVICES AND FOR THE
SELECTION OF THE VENDOR FOR PURCHASING ANY PRODUCT. THE OPTIC MODULES AND CABLES REFERRED TO ABOVE ARE NOT
WARRANTED OR SUPPORTED BY INTEL. INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR
IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF SUCH THIRD PARTY PRODUCTS OR SELECTION OF VENDOR BY
CUSTOMERS.
Connect the Twinaxial Cable
Insert the twinaxial network cable as shown below.
Type of cabling:
l
10 Gigabit Ethernet over SFP+ Direct Attached Cable (Twinaxial)
l
Length is 10 meters max.
Insert the Mezzanine Card in the Blade Server
1. Turn off the blade server and pull it out of the chassis, then remove its cover.
CAUTION: Failure to turn off the blade server could endanger you and may damage the card or
server.
2. Lift the locking lever and insert the card in an available, compatible mezzanine card socket. Push the card into
the socket until it is firmly seated.
NOTE:
A switch or pass-through module must be present on the same fabric as the card in the chassis to
provide a physical connection. For example, if the mezzanine card is inserted in fabric B, a switch must
also be present in fabric B of the chassis.
3. Repeat steps 2 for each card you want to install.
4. Lower the locking lever until it clicks into place over the card or cards.
5. Replace the blade server cover and put the blade back into the server chassis.
6. Turn the power on.