SUBJECT: GIII Plus Validator Adapter Plate Installation
MODELS: All GIII Plus models
KIT NUMBER
KIT DESCRIPTION
355585SRV
Validator Adapter Plate
TOOLS REQUIRED: 11/32" (9 mm) socket or nut driver
ESTIMATED INSTALLATION TIME: <15 minutes
ANy QUESTIONS? ContACt RoyAl VendoRS’ CuStomeR SeRVICe dePARtment
IN NORTh AMERICA, CALL TOLL FREE 1 800 931 9214
F0019003.FRM
REV.: C
ISSUE DATE: 05 JUN 1995
REV. DATE: 05 DEC 2003
359
426 Industrial Boulevard • Kearneysville WV 25430-2776 • USA
Telephone:
+1 304 728 7056 • [email protected]
Toll-free in North America:
1 800 931 9214 •
Fax:
+1 304 725 4016
Canada:
+1 905 738 5777 •
Mexico:
+52 55 5203 6887
Europe:
+49 2158 95 1000 •
Australia:
+61 2 9890 5433
REASON FOR BULLETIN:
this bulletin describes the procedure for installing the Validator Adapter Plate,
which allows for the installation of both a bill validator and a card reader in the GIII Plus venders.
INSTALLATION INSTRUCTIONS:
NOTE:
Before working on the vender, always remove power by unplugging the vender's power cord from the AC voltage source (wall outlet).
1. unplug the harnessing to the bill validator (if currently installed). then, using an 11/32" (9 mm) socket or nut
driver, remove the four nuts that secure the bill validator.
(Refer to Figure 1.)
once these are removed, pull
the validator straight out of the door.
2. Remove the four nuts that secure the validator filler plate in the vender's door.
(Refer to Figure 1.)
Remove
the filler plate.
3. mount the validator adapter plate in the opening where the filler plate was. Secure it with the four nuts that
were removed in Step 2.
(Refer to Figure 2.)
4. mount the card reader where the bill validator was previously mounted (lower hole). Secure it with the four
nuts that were removed in Step 1.
5. mount the bill validator onto the validator adapter plate. Secure it with the four nuts from the kit.
6. Connect all harnessing to the validator and to the card reader as required.
R
Page:
1 of 2
Date:
8 June 2012
Revision:
00
SERVICE BULLETIN
Number of
People
Required
In an effort to provide our customers with the latest information on our equipment, Royal Vendors sends service bulletins to customers using the original ship-to address or
e-mail addresses, if supplied by our customers. We also post all service bulletins on our website at www.royalvendors.com. If for any reason a vender is moved to another
location or is sold to another customer other than to whom Royal Vendors originally sent the machine, it is the responsibility of the original purchaser of the vender to notify
the appropriate personnel of the service bulletin.
The following areas of this vender contain voltage which can
cause serious injury or even death: the main power cord,
supplying 115-230 VAC to the evaporator, EMI filter, and
refrigeration system; the power line from the EMI filter to the
ballast and transformer; and the ballast, which can produce
upwards of 600 volts. Remove all power from the vender before
working in any of these areas.