Appendix A Parameter Table
- 97 -
Param.
No.
Param. Name
Setting Range
Default
Property
A8-35 Equipment fault
action selection 0
Ones: Solenoid valve overcurrent (E95)
0: Coast to stop
2: Restart allowed
5: Canceled
Tens: Phase sequence abnormal (E96)
0: Coast to stop
5: Canceled
Hundreds: Output phase loss of mains
frequency cooling blower (E97)
0: Coast to stop
2: Restart allowed
5: Canceled
Thousands: Reserved
Ten thousands: Reserved
55202
0: Coast to
stop
2: Restart
allowed
5: Canceled
☆
A8-39 Output current cali-
bration coefficient
70.0 to 120.0
100.0
☆
A8-40 Output power calibra-
tion coefficient
70.0 to 120.0
100.0
☆
A8-41 Pressure calibration
coefficient
0.0 to 200.0
100.0
☆
A8-42 Temperature calibra-
tion coefficient
0.0 to 200.0
100.0
☆
A8-43 Accumulative with-
load running time
0 to 65535h
0h
☆
A8-44 Running time under
pressure pre-warning 0 to 65535h
0h
☆
A8-45
Running time un-
der temperature
pre-warning
0 to 65535h
0h
☆
A8-46
Enabling bit of pres-
sure and temperature
sensor 2
Ones: Pressure 2
0: Disabled
1: Enabled
Tens: Temperature 2
0: Disabled
1: Enabled
00
☆
A8-47 Set pre-warning value
of pressure 2
0 to 65535 Mpa
0 Mpa
☆
A8-48 Set protection value
of pressure 2
0 to 65535 Mpa
0 Mpa
☆
A8-49 Set pre-warning value
of temperature 2
0 to 65535℃
0℃
☆
A8-50 Set protection value
of temperature 2
0 to 65535℃
0℃
☆
A8-51
Jog command for
mains frequency
cooling blower
0 to 65535
0
☆
A8-52 Special function
enabling bit
0 to 65535
1
☆