Appendix A Parameter Table
- 65 -
Param.
No.
Param. Name
Setting Range
Default
Property
F2-54 Generating power
limit
0.0% to 200.0%
0.0%
★
Group F3: V/F Control Parameters
F3-00 V/F curve setting
0: Linear V/F
1: Multi-point V/F
2: Square V/F
3: 1.2-power V/F
4: 1.4-power V/F
6: 1.6-power V/F
8: 1.8-power V/F
10: V/F complete separation
11: V/F half separation
0
★
F3-01 Torque boost
0.0%: Automatic torque boost
0.1% to 30.0%
Model depen-
dent
☆
F3-02
Cut-off frequency of
torque boost
0.00 Hz to the maximum frequency
50.00 Hz
★
F3-03 Multi-point V/F fre-
quency 1
0.00 Hz to F3-05 (Multi-point V/F frequency
2)
0.00 Hz
★
F3-04 Multi-point V/F volt-
age 1
0.0% to 100.0%
0.0%
★
F3-05 Multi-point V/F fre-
quency 2
F3-03 (Multi-point V/F frequency 1) to F3-
07 (Multi-point V/F frequency 3)
0.00 Hz
★
F3-06 Multi-point V/F volt-
age 2
0.0% to 100.0%
0.0%
★
F3-07 Multi-point V/F fre-
quency 3
F3-05 to F1-04 (Rated motor frequency)
0.00 Hz
★
F3-08 Multi-point V/F volt-
age 3
0.0% to 100.0%
0.0%
★
F3-09 V/F slip compensation
gain
0.0% to 200.0%
0.0%
☆
F3-10 V/F over-excitation
gain
0 to 200
64
☆
F3-11 V/F oscillation sup-
pression gain
0 to 100
Model depen-
dent
☆
F3-12 Oscillation suppres-
sion gain function
0: Disabled
3: Enabled
3
★
F3-13 Voltage source for V/F
separation
0: Set by F3-14
1: AI1
2: AI2
4: Pulse setting (DIO1)
5: Multi-reference
6: Simple PLC
7: PID
8: Communication setting
0
☆
F3-14 Digital setting of volt-
age for V/F separation 0 V to the rated motor voltage
0 V
☆