Appendix A Parameter Table
- 92 -
Param.
No.
Param. Name
Setting Range
Default
Property
A1-05 VDI state setting
mode
0: Set by A1-06
1: DO state
2: DI state
Ones: VDI1
Tens: VDI2
Hundreds: VDI3
Thousands: VDI4
Ten thousands: VDI5
00000
★
A1-06 Selection of VDI active
state
0: Disabled
1: Enabled
Ones: VDI1
Tens: VDI2
Hundreds: VDI3
Thousands: VDI4
Ten thousands: VDI5
00000
☆
A1-07 Function selection for
AI1 used as DI
Refer to the description of F4-00.
0
★
A1-08 Function selection for
AI2 used as DI
Refer to the description of F4-00.
0
★
A1-10 Active state selection
for AI used as DI
Ones: AI1
0: High level active
1: Low level active
Tens: AI2
0: High level active
1: Low level active
00
★
Group A
4:
Air Compressor PID Control
A4-00 Air compressor con-
trol mode
0 to 65535
0
☆
A4-01 Open-loop control
frequency setting
0 to 65535
0
☆
A4-02 Model switchover
frequency ratio
20% to 60%
45
☆
A4-03 Control interval
0 to 65535 ms
0
☆
A4-04 Model proportional
coefficient
0 to 65535
0
☆
A4-05 Model time constant 0 to 65535
0
☆
A4-06
Motor acceleration/
deceleration and
pipeline lag time
constant
0 to 65535
0
☆
A4-07 Air tank volume
0 to 65535 L
0
☆
A4-08 Air compressor vol-
ume flow
0 to 65535
0
☆
A4-09 Parameter calculation
times
0 to 65535
0
☆