3 Display Description and Commissioning
- 37 -
On the "User Parameters" page, set parameters related to the air end and cooling
blower, as shown in Figure 3-7.
Menu
Air end
settings
Back
Cooling
blower
settings
Discharge pressure
0.70
MPa
Sleeping pressure
0.80
MPa
Transition frequency
60.00
Hz
Sleep determination time
20
s
Transition time
10
s
Sleep wake-up
pressure
0.60
MPa
Air end stop delay
3
s
Shutdown and blocking
time
3
s
Pressure (Kp)
10.0
Pressure (Ti)
0.30
Discharge temperature
80
℃
Stopping temperature
75
℃
Starting temperature
85
℃
Temperature (Ti)
2.00
Temperature (Kp)
20.0
User Parameters
Figure 3-7 User parameter settings (example)
4)
Touch "Maintenance Parameters" and "Protection Parameters" in sequence to set
parameters related to the air compressor.
Menu
Maintenance Parameters
Running time of
lubricating oil filter
6
H
Maintenance period of
lubricating oil filter
2000
H
Running time of
oil and gas separator
6
H
Maintenance period of
oil and gas separator
2000
H
Running time of
lubricating oil
6
H
Maintenance period of
lubricating oil
2000
H
Running time of air filter
6
H
Maintenance period of
air filter
2000
H
Running time of
motor lubricating grease
6
H
Maintenance period of
motor lubricating grease
2000
H
Figure 3-7
Maintenance parameter settings (example)