Appendix A Parameter Table
- 87 -
Param.
No.
Param. Name
Setting Range
Default
Property
Group Fd: Communication Parameters
Fd-00 Modbus baud rate
0: 300 bps
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps
8: 57600 bps
9: 115200 bps
7
☆
Fd-01 Modbus data format
0: No check (8-N-2)
1: Even parity check (8-E-1)
2: Odd parity check (8-O-1)
3: 8-N-1
0:
☆
Fd-02 Modbus local address 1 to 247 (0: Broadcast address)
1
☆
Fd-03 Modbus response
delay
0 ms to 20 ms
2
☆
Fd-04 Modbus communica-
tion timeout
0.1s to 60.0s
0.0: Disabled
0
☆
Fd-06 Auto reset of commu-
nication fault
0: Disabled
1: Enabled
1
☆
Fd-07
Communication be-
tween power supply
and drive units
0: Disabled
1: Enabled
1
★
Fd-09 Communication sta-
tus
Ones (CANopen)
0: Stop
1: Initialization
2: Pre-operational
8: Operational
Tens (CANlink)
0: Stop
1: Initialization
2: Pre-operational
8: Operational
Hundreds (Profibus DP)
0: Stop
1: Initialization
8: Operational
0
●
Fd-10 CANopen/CANlink
switchover
1: CANopen
2: CANlink
1
★
Fd-11 CANopen 402
0: Disabled
1: Enabled
0
★