88-A951X001-1D-EN
85
1.
Remove 3” plug on right side of unit. To be used for condensate
trap.
2.
Install condensate trap grommet.
3.
Remove 3” plugs on the left side of the cabinet. To be used for
combustion air inlet.
4.
Reuse the two 3” plugs to seal the two 3” default openings on the
top of the furnace.