Document Pack Contents
Item
Qty.
Description
S
SA
AF
FE
ET
TY
Y
W
WA
AR
RN
NIIN
NG
G
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
May 2020
8
88
8--A
A9
95
51
1X
X0
00
01
1--1
1D
D--E
EN
N
Upflow/Horizontal and Dedicated Downflow
Gas-Fired, Direct/Non-Direct Vent, Single Stage Condensing
Furnaces with High Efficiency Motor
U
Up
pffllo
ow
w,, C
Co
on
nv
ve
errttiib
blle
e tto
o
H
Ho
orriizzo
on
ntta
all R
Riig
gh
htt o
orr
H
Ho
orriizzo
on
ntta
all L
Le
efftt
A951X040BU3SAB
A951X060BU4SAB
A951X080BU4SAB
A951X080CU5SAB
A951X100CU5SAB
A951X120DU5SAB
D
Do
ow
wn
nffllo
ow
w O
On
nlly
y
A951X040BD3SAB
A951X060BD3SAB
A951X080BD4SAB
A951X100CD5SAB
A951X120DD5SAB
N
No
otte
e:: Graphics in this document are for representation
only. Actual model may differ in appearance.
88-A951X001-1D-EN
Installer’s Guide
CAUTION
COIL REQUIREMENT!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit. See Installer’s Guide for more information.
▲
!
1
1
Condensate Drain Tube Assembly
2
1
Inlet Vent
(a)
3
1
Inlet Vent Gasket
4
1
Outlet Vent Assembly
5
1
Outlet Vent Gasket
6
6
Screws
7
1
Condensate Trap Grommet
8
1
Plug — Condensate/Gas
9
1
Plug — Electrical
10
2
Grommet — Condensate/Gas
11
1
Installer’s Guide
12
1
Service Facts
13
1
Owner Guide
14
1
Limited Warranty
15
1
2” to 3” Coupling — CPL00938
(b)
16
2
Tinnerman Clips (not pictured)
Note:
Tinnerman Clips should be
kept with unit and are used
if the door panel flange hole
(s) becomes stripped.
17
2
Brand labels
(c)
(a)
3” inlet vent supplied with A951X120DU and A951X120DD only. 2” inlet vent supplied with all other models.
(b)
Supplied with A951X120DU and A951X120DD only
(c)
Place appropriate brand label below the warning label on the front panel using stencil marks as guides.
A
Acccce
esssso
orriie
ess
Содержание A951X040BD3SAB
Страница 13: ...88 A951X001 1D EN 13 Outline Drawings Upflow Furnace B Size Cabinet ...
Страница 14: ...14 88 A951X001 1D EN Upflow Furnace C Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 15: ...88 A951X001 1D EN 15 Upflow Furnace D Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 16: ...16 88 A951X001 1D EN Downflow Furnace B Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 17: ...88 A951X001 1D EN 17 Downflow Furnace C Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 18: ...18 88 A951X001 1D EN Downflow Furnace D Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 102: ...102 88 A951X001 1D EN N No ot te es s ...
Страница 103: ...88 A951X001 1D EN 103 N No ot te es s ...