82
88-A951X001-1D-EN
1.
Remove three inducer screws.
2.
Loosen hose clamp and remove 45 degree adapter. If the rubber
boot pulls out of the inducer opening, remove from the adapter
and reinstall onto the inducer.
3.
Rotate the inducer so that the outlet is pointing vertically.
4.
Use the three inducer screws to reattach the inducer to the cold
header. Torque to 30 in.-lbs. Do not overtighten.
1.
Remove condensate drain plug from top right location on cold
header.
2.
Place condensate drain plug onto the cold header outlet located
on the bottom left of the cold header.
1
2
F
Fu
urrn
na
acce
e C
Co
om
mb
bu
ussttiio
on
n A
Aiirr E
Ex
xh
ha
au
usstt O
Op
pttiio
on
nss