Furnace General Installation
The following sections give general instructions for the
installation of the gas furnaces.
Note:
For the A951X furnace, a 1/4” nut driver is required to remove
the two screws at the top of the front panel. The front panel can
then be removed by lifting upwards.
Horizontal Installation in an Attic
or Crawlspace
The upflow condensing furnace may be installed in an
attic or crawl space in the horizontal let or right
position for needed airflow direction. The horizontal
furnace installation in an attic should be on a service
platform large enough to allow for proper clearances
on all sides and service access to the front of the
furnace. See
“the Locations and Clearance section,” p.
12
. Line contact is only permissible between lines
formed by intersections of the top and two sides of the
furnace casing and building joists, studs, or framing.
The furnace may be placed horizontally in a crawl
space on a pad or other noncombustible material
which will raise the unit for sufficient protection from
moisture.
The Furnace must be supported at both ends when
installed horizontally. The Furnace must also be
elevated approximately 6 inches to allow clearance for
the condensate drain to exit the cabinet in the
h
ho
orriizzo
on
ntta
all p
po
ossiittiio
on
n..
TO APPROVED
OPEN / VENTED DRAIN
FURNACE MUST BE SUPPORTED AT ALL FOUR
CORNERS. BAYHANG - OPTIONAL HORIZONTAL
HANGING BRACKET KIT
Note: The overflow stand pipe termination must be even with or slightly below
the bottom of the condensate trap.
Note: Water from the overflow pipe must drain into the emergency drain pan.
H
Ho
orriizzo
on
ntta
all IIn
nsstta
alllla
attiio
on
n H
Ha
an
ng
giin
ng
g U
Ussiin
ng
g S
Sttrra
ap
pss
The furnace may be installed hanging in a hanging
position using straps. The furnace should be supported
at both ends and have an additional support in the
center of the furnace in front.
Содержание A951X040BD3SAB
Страница 13: ...88 A951X001 1D EN 13 Outline Drawings Upflow Furnace B Size Cabinet ...
Страница 14: ...14 88 A951X001 1D EN Upflow Furnace C Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 15: ...88 A951X001 1D EN 15 Upflow Furnace D Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 16: ...16 88 A951X001 1D EN Downflow Furnace B Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 17: ...88 A951X001 1D EN 17 Downflow Furnace C Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 18: ...18 88 A951X001 1D EN Downflow Furnace D Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 102: ...102 88 A951X001 1D EN N No ot te es s ...
Страница 103: ...88 A951X001 1D EN 103 N No ot te es s ...