Sequence of Operation
G
Ga
ass H
He
ea
attiin
ng
g
1. R – W contacts close on the thermostat sending
24VAC to the W1 low voltage terminal of the IFC.
Technician should read 24VAC from W1 to B/C. The
seven-segment LED will read:
Xt
= Gas Heating
2. The IFC performs a self-check routine and then
confirms that the:
a. Condensate pressure switch and Inducer limit
switch are closed by sending 24VAC out the
HLO terminal and monitoring the ILI input.
b. Flame roll-out switches (FRS) 1 & 2, main
thermal limit (TCO), and any reverse air flow
(RAF) switches are closed by sending 24VAC out
the HLO terminal and monitoring the HLI input.
c. Pressure switch 1 (PS1) is opened by sending
24VAC out the HLO terminal, through the limit
switches, and monitoring the PS1 input.
N
No
otte
e:: If a thermal limit is open, 24VAC will not be
present at the pressure switch.
3. After steps a, b, and c are confirmed, the inducer
relay is closed energizing the inducer motor.
4. As the inducer ramps up, PS will close.
5. When PS closes, the ignitor relay on the IFC will
close. The ignitor is energized. The ignitor warm up
is approximately 17 seconds.
6. After the ignitor warm up, the gas valve relay is
closed, which energizes the gas valve solenoid to
allow ignition.
7. The first burner will ignite, and flame will crossover
to the remaining burners, establishing current to
the flame sensor. Proof of flame must be
established within 4 seconds.
N
No
otte
e:: There are two flame sense pads located on
the IFC marked as “FP”. To measure the
flame current, use a VOM set to DC volts.
1VDC = 1 micro-amp. Flame current will vary
depending on the type of meter used. Typical
flame current ranges from 0.75 – 3.0 micro-
amps (0.75 – 3 VDC).
8. Once flame sense has been established, a timer on
the IFC starts, and the indoor blower will energize
after the blower “Heat On Delay” has completed..
The seven-segment LED for example will
alternately read:
Xt
= Gas heating
TP5
= Speed Tap 5
9. When the temperature raises enough to satisfy the
thermostat setting, contacts R-W will open.
10. The gas valve relay will open, closing the gas valve.
The inducer will continue to run for approximately 5
seconds to remove any combustion by-products
from inside the furnace.
11. The indoor blower continues to run to remove heat
from the heat exchangers. The blower off time is
field adjustable through the IFC menu setup option.
The seven segment LED will read
IDL
= Idle, no
thermostat demand.
C
Co
oo
olliin
ng
g // H
He
ea
att P
Pu
um
mp
p
1. R-Y1-G contacts on the thermostat close sending
24VAC to the Y1 and G low voltage terminals on the
IFC. Technician should read 24VAC between Y1-B/C
and between G-B/C.
2. 24VAC is sent to the OD unit via thermostat wiring.
3. The indoor blower ramps to the cooling / heat
pump airflow. The seven-segment LED, for
example, will alternately read:
CP1
= Cooling / Heat Pump
tp7
= Speed Tap 7
4. When the temperature is lowered / raised (PH
mode) enough to satisfy the thermostat setting,
contacts R-Y-G will open.
5. The OD unit shuts off and the indoor blower shuts
off, unless a blower “Cool Off Delay” has been
enabled in the IFC setup menu options. The seven-
segment LED will read
IDL
= Idle, no thermostat
demand.
Содержание A951X040BD3SAB
Страница 13: ...88 A951X001 1D EN 13 Outline Drawings Upflow Furnace B Size Cabinet ...
Страница 14: ...14 88 A951X001 1D EN Upflow Furnace C Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 15: ...88 A951X001 1D EN 15 Upflow Furnace D Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 16: ...16 88 A951X001 1D EN Downflow Furnace B Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 17: ...88 A951X001 1D EN 17 Downflow Furnace C Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 18: ...18 88 A951X001 1D EN Downflow Furnace D Size Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 102: ...102 88 A951X001 1D EN N No ot te es s ...
Страница 103: ...88 A951X001 1D EN 103 N No ot te es s ...