28
Installation Precheck
Power on the unit if it is not already on. Observe the power-button light on the case lid and compare it to
the "operational status" column in Table 3.6 below.
•
If there are no errors or issues,
shut down the unit.
•
If there are any issues, recheck the work completed to this point. If an issue persists, contact Industrial
Scientific.
Table 3.6 Power-button light indicators
Color and state
Operational status
Green only
Solid (not blinking)
The unit is operational.
Rapid blinking
The unit is trying to communicate with iNet.
Slow blinking
Very
slow blinking
(once every 4 seconds)
The unit is communicating with iNet but its GPS* is not working.
or
The unit cannot communicate with iNet.
RGX is set to LENS repeater mode.
Both green and red
Alternating
Low battery warning
or
The power button has been pressed and the unit is shutting down.
Red only
Solid (not blinking)
The unit is not operational because there is no power.
Rapid blinking
Indicates that wi-fi access mode has been activated
Slow blinking
Indicates that the unit is inactive (never activated or currently
deactivated), See also
or
An error has occurred that requires resolution. Power off, then
power on the unit. If the issue persists, contact Industrial Scientific
Light is off
The unit is powered off or the battery is completely discharged.
*Status is indicated only when feature is enabled.
Содержание RGX Series
Страница 22: ......
Страница 26: ......
Страница 48: ......
Страница 58: ...48 Figure A 1 B External electrical connections in a nonhazardous location To Figure A 1 A ...
Страница 59: ...49 Figure A 1 C Internal electrical connections ...
Страница 60: ......