Table 1.4 RGX Gateway intrinsic safety (IS) input parameters
Item
Value
Ui
16.2 VDC
Ii
0.980 A
Pi
2.2 W
Ci
0 µF
Li
0 mH
The RGX Gateway can be operated using customer-supplied, customer-installed fixed DC power that
supplies a compatible input voltage range of 9
–
30 VDC with a maximum current of 5.0A connected to the
dedicated ports on the RGX terminal block. Before connecting power, read and understand control drawing
1810D9509-200, as represented by the schematic diagrams in
The charging power supply and power cord (part number 17158665) can be used to provide operational
power to the unit
only when
the unit is operated in a nonhazardous location.
Specifications
RGX Gateway specifications
Ensure all aspects of installation and operation are consistent with the product specifications listed below.