34
Figure 4.2
If your installation
excludes
connecting
both
fixed DC power
and
Ethernet,
continue below with step 1; otherwise, use the instruction set in Figure 4.3.
─
1
Mount or place RGX
If the unit has been prepared for mounting, use the customer-supplied equipment and services
to complete the mounting task; otherwise place the unit at the desired operational location.
2
Port caps and power cables
─
Choose
only
one option below (a, b, or c) regarding the operational power input for the RGX
and follow that set of instructions.
WARNING:
The RGX offers these power-input options: 12 V Charger Port, IS Power Port, and
9
–
30 VDC Terminal Block. When connecting external power, select only a single power-input
type;
connecting multiple power inputs is
not supported
.
When installing a port cap or connecting a power supply cable to a port, push the cap or cable
slightly, then turn its swivel connector clockwise (approximately 45°) until it clicks closed or a
full-stop connection feedback is felt.
a No external power source
If the RGX will draw operational power
only
from its factory-installed battery, cap the charging
power-supply port
and
the IS power port.
b Power supply accessory (ISERTPS or ERTPS)
IMPORTANT
:
The
warning
above also applies to this option.
If the RGX will draw operational power from a compatible power supply accessory, cap the
RGX charging power-supply port.
Ensure the ISERTPS or ERTPS is installed, connected, and used in accordance with the
instructions provided in its product manual.
c Charging power supply (part number 17158665)
—
use
only
in a nonhazardous location
IMPORTANT
:
The
warning
above also applies to this option.
If the unit will be operated in a nonhazardous location and will draw operational power using
the RGX charging power supply, cap the RGX IS power port.
Uncap the unit's charging power supply port to expose the port for use; connect the power-
supply cable to the port. Plug the cord into a compatible electrical outlet.
Figure 4.2 Installation that
excludes
fixed DC power
and
Ethernet
Содержание RGX Series
Страница 22: ......
Страница 26: ......
Страница 48: ......
Страница 58: ...48 Figure A 1 B External electrical connections in a nonhazardous location To Figure A 1 A ...
Страница 59: ...49 Figure A 1 C Internal electrical connections ...
Страница 60: ......