23
RGX Gateway operating in LENS repeater mode
Site name can be set. All other settings must be edited in iNet.
Save and Reboot
When finished, click save; the Interface will prompt you to confirm the save.
When prompted to reboot, click on the prompt, then confirm. No other action is needed, the software
will complete the reboot.
5
Verify RGX Gateway operation
To verify the unit is operational, observe the power-button light. If it is green and not blinking, the unit
is operational. For information about other indicator-light patterns and colors, see
Next go to
and follow the instructions to use iNet, where you will complete all other
settings
.
Figure 3.3 Wi-fi access method for RGX Configuration Interface
Figure 3.4
1
Shut down the RGX
Set the unit on the work surface, case lid facing up.
Observe the power-button light.
•
If the light is
off,
continue.
•
If the light is on and
green
only (blinking or solid),
shut down the
unit
. Press the power button for approximately 7 seconds; when its
light starts blinking, release the button. The power-button light will
blink red and green to indicate shutdown is in progress; it will turn
off to indicate the unit is fully shutdown.
•
If the light is on and includes
red
light (blinking or solid),
3.6 Power-button light indicators
before continuing
.
2
Access unit interior
Using a torx screwdriver with a T25 bit, unscrew and remove the four
screws that secure the case lid to the case base.
Set aside the screws for later reinstallation.
The case is hinged on the left; open its lid from right to left.