41
Figure 5.2 Instructions for service items installed on the case
exterior
: mounting kits and IS cable adapter.
Wall Mount Kit installation
—
Using the orientation shown, mate the hexagon cutout of the wall
mount to a corresponding corner on the back of the RGX.
The cross portion will extend past the edge of the case.
Using a T30 torx screwdriver,
turn the torx screw clockwise
to tighten.
Screw torque: 1.13 to 1.69
Nm (160 to 240 oz in)
Install the remaining wall
mounts.
—
In the kit, locate the supplied
label, which replicates
important information printed on
the back of the RGX.
Locate the unit’s LAN MAC
and WAN MAC values, printed
on the factory affixed label on
the back of the unit. Record
these two values onto the kit
label in the areas provided.
Affix the kit label to an area of
the RGX that will be visible
during operation.
Magnet Mount Kit installation
Do not use
with a unit that will draw power from a DC fixed power source.
Insert magnet post into a threaded screw hole on the back of the
case; turn clockwise to tighten.
Repeat for second magnet installation.
The two magnets may be installed in the following
configurations: top, bottom, left side, right side, and diagonal.
Two magnet mounts will support the weight of the RGX; up to
four magnets may be installed.
Содержание RGX Series
Страница 22: ......
Страница 26: ......
Страница 48: ......
Страница 58: ...48 Figure A 1 B External electrical connections in a nonhazardous location To Figure A 1 A ...
Страница 59: ...49 Figure A 1 C Internal electrical connections ...
Страница 60: ......