RGX Gateway
–iNet communication
The RGX Gateway is set, by the customer, to communicate with iNet using one or more options
—
wi-fi,
cellular, and Ethernet. The options you can select may be limited by your company's communication
preferences and security guidelines. See your network administrator if you are not familiar with your
company's communication protocols. For deployment planning and setup preparation, determine the
following.
•
Decide which of the three communication options a unit will use.
•
If a unit will use more than one of these options, decide the priority order in which they will be used. For
example, if both wi-fi and cellular will be used, a unit can be set to first use wi-fi and if that is not
available, use cellular.
•
If a unit will use Ethernet or wi-fi determine the type of "network protocol" connection it will use
—
dynamic
(a.k.a., DHCP or Dynamic Host Configuration Protocol) or
static
. If this setting is unknown to
you, contact your network administrator.
Wireless Settings and Connections
The settings itemized in Table 2.1 are required for iNet Now live monitoring of LENS group peers.
Table 2.1 Required equipment settings for iNet Now live monitoring
Equipment items
Setting item
RGX Gateway
a
Ventis Pro
Radius BZ1
LENS Wireless
No setting required
Menu: Wireless
Setting: LENS Wireless
Value: iNet Now and Local
Menu: Wireless
Setting: Wireless Radio
Value: iNet Now and Local
LENS Wireless Group
b
Menu: LENS Wireless
Setting: LENS Group
Value: Group X
c
Menu: Wireless
Setting: LENS Wireless,
LENS Group
Value: Group X
c
Menu: Wireless
Setting: Group
Value: Group X
c
Encryption key
a
Menu: LENS Wireless
Setting: Encryption Key
Valued
d
: Automatic or custom
Menu: Wireless
Setting: LENS Wireless,
Encryption
Value
d
: Automatic or custom
Menu: Wireless
Setting: Encryption
Value
d
: Default or custom
a
Also applies to RGX units operating in LENS repeater mode.
b
All equipment items must be set to the same LENS Wireless group and encryption key.
c
"X" is used here to indicate the value will be a single character in length; the available values are the letters A through J.
d
"Default" sets the unit's LENS Wireless to the Industrial Scientific encryption key, and "custom" to the customer's key. If a custom key will