Imagine Platinum IP3 Скачать руководство пользователя страница 3

Platinum™ IP3 
Installation and Operation Manual 

 

Contents

 

 

© 2016 Imagine Communications Corp.

          

Proprietary and Confidential.

 

September 2016 | Page 3 

 

Contents 

Preface ................................................................................................................. 14

 

Manual Information ............................................................................................................................... 14 

Purpose ............................................................................................................................................... 14 
Audience ............................................................................................................................................. 14 
Revision History .................................................................................................................................. 14 
Obtaining Documents ......................................................................................................................... 15 

Unpacking/Shipping Information ........................................................................................................... 15 

Unpacking a Product .......................................................................................................................... 15 
Returning a Product ........................................................................................................................... 15 

Safety ...................................................................................................................................................... 16 
Standards ................................................................................................................................................ 16 
Waste from Electrical and Electronic Equipment (WEEE) Compliance .................................................. 16 

Introduction ......................................................................................................... 18

 

Platinum IP3 Overview ........................................................................................................................... 18 

Product Description ............................................................................................................................ 18 
Platinum IP3 28 RU (PX-FR-28) and 15 RU (PX-FR-15) Frames ........................................................... 18 
Features .............................................................................................................................................. 19 
Platinum IP3 Architecture .................................................................................................................. 20 
Removing the Frame Door ................................................................................................................. 21 

Frame Architecture ................................................................................................................................. 23 

28 RU Platinum IP3 Front View .......................................................................................................... 23 
15 RU Platinum IP3 Front View .......................................................................................................... 24 
28 RU Platinum IP3 Rear View............................................................................................................ 25 
15 RU Platinum IP3 Rear View............................................................................................................ 26 
28 RU Platinum IP3 Frame Architecture ............................................................................................ 27 
15 RU Platinum IP3 Frame Architecture ............................................................................................ 28 
Platinum IP3 Physical Specifications .................................................................................................. 28 

Frame Modules ....................................................................................................................................... 29 
Power Consumption ............................................................................................................................... 31 

Power Consumption of Frame and Input/Output Modules ............................................................... 31 
Platinum IP3 Power and Temperature Specifications ........................................................................ 32 

Expansion Overview ............................................................................................................................... 33 

Содержание Platinum IP3

Страница 1: ...Platinum IP3 28 RU and 15 RU Frame and Modules September 2016 Edition I Installation and Operation Manual...

Страница 2: ...t notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the product Trademarks Platinum Platinum IP3 Magellan...

Страница 3: ...ction 18 Platinum IP3 Overview 18 Product Description 18 Platinum IP3 28 RU PX FR 28 and 15 RU PX FR 15 Frames 18 Features 19 Platinum IP3 Architecture 20 Removing the Frame Door 21 Frame Architecture...

Страница 4: ...ansion Modules 40 Crosspoint Modules 40 Monitoring Modules 41 Output Monitoring Modules 41 Multiviewer Modules 41 Resource Module PX RES 42 Resource Module PX RES Overview 42 PX RES in a Platinum fram...

Страница 5: ...66 Power Consumption 67 Output Monitoring Modules 68 PX HSRAEC OM Output Monitoring Module 68 Notes 68 Controllable Parameters 70 Video Crosspoint Module PX 576x1024 3G PX 288x512 3G 72 28 RU Video C...

Страница 6: ...nerator 93 Polarity Reversal 93 Channels Swapping and Summing 93 Redundancy 93 Frame Expansion 93 LED Indicators 94 Hardware Connections for Audio Expansion 95 Audio Expansion Connection Status in the...

Страница 7: ...OB Expansion 121 Inserting Output Modules into the Platinum IP3 frame 121 Failsafe Mode 121 Signal Presence and LEDs 122 System LEDs 122 Module LEDs 123 Controllable Parameters 123 Parameter Notes 123...

Страница 8: ...xing Input Modules PT FSDMX IBG PT FSDMXO IBG PT FSDX8C1D IBG PT FSDMX8O1D IBG 140 Back Module Variants 141 Electrical BNC Back Module PT FSDMX IBG 142 Optical SFP Back Module PT FSDMXO IBG 142 Electr...

Страница 9: ...ng 167 Video Processing 168 Quiet Audio Switching 169 PX HSRMX OBG Specifications 170 Electrical Output Back Module with 16 HD BNCs 170 Electrical Output Back Module with DensiShield 170 Optical Outpu...

Страница 10: ...Parameters 208 Analog Digital Audio Converter Modules with TDM 212 Audio A D Input Modules with TDM Capability PT ADCT IB 212 Operation 212 Installation 215 Control 215 Controllable Parameters 215 Fun...

Страница 11: ...244 Analog Composite Video Modules 245 Analog Video to SDI Decoder Input Modules PT DEC IB 245 Operation 245 Installation 247 Control 247 Controllable Parameters 247 Functional Block Diagram 249 Spec...

Страница 12: ...rame 274 Power Distribution Zones 275 Power Distribution Modules 277 Top Power Distribution Module PX PD TOP 277 Bottom Power Distribution Module PX PD BOT 280 Power Supply Specs LEDs and Pinouts 281...

Страница 13: ...300 Output 1 Output 6 300 Output 7 Output 8 Output 9 300 Output 13 Output 14 Output 15 Output 16 300 Module Interconnect PX BP 28 PX BP 15 302 PX BP 28 PX BP 15 Module Slots 302 Fuses on the Module I...

Страница 14: ...14 Third Release D February 2015 Support for PX RES in Platinum 5 RU and 9 RU Frames See PX RES in a Platinum frame on page 42 E October 2015 New 15 RU Platinum IP3 frame F December 2015 Minor edits t...

Страница 15: ...ted components before you install the unit Keep at least one set of original packaging in the event that you need to return a product for servicing Returning a Product In the unlikely event that your...

Страница 16: ...cedures Table 1 Safety Terms and Symbols in this Manual WARNING Statements identifying conditions or practices that may result in personal injury or loss of life High voltage is present CAUTION Statem...

Страница 17: ...ies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycled See our website for more information Contact your local sales representat...

Страница 18: ...video audio and embedded audio routing within a single flexible frame The Platinum IP3 routing switcher system provides video matrix expandability 9x16 to 576 1024 in a single 28 RU frame or 288x512 i...

Страница 19: ...from the front via a removable door Status LEDs can be viewed through this door these LEDs indicate power supply presence and status resource module usage and link light indicators for Ethernet commun...

Страница 20: ...eo signals while keeping a versatile frame and control system This combination allows high performance multi format video audio and embedded audio routing within a single flexible frame The IP3 can sw...

Страница 21: ...tial September 2016 Page 21 Removing the Frame Door Note While you can just open the front door of the Frame you may want to remove it completely when you need better access to Modules While pressing...

Страница 22: ...Platinum IP3 Installation and Operation Manual Introduction 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 22 Figure 3 15 RU IP3 Frame and close up of locking pin...

Страница 23: ...atinum IP3 Front View Power Supplies Outputs 1 256 MI Backplane Outputs 257 512 Outputs 513 768 PT SYNC 1 2 Resource Modules PX RES 1 2 Outputs 769 1024 Power Supplies Power Supplies Inputs 433 576 In...

Страница 24: ...onfidential September 2016 Page 24 15 RU Platinum IP3 Front View Power Supplies Power Supplies Outputs 1 256 Video Crosspoint 1 Outputs 257 512 PT SYNC 1 2 Resource Modules PX RES 1 2 Audio TDM Crossp...

Страница 25: ...6 28 RU Frame Rear View Important Rear Filler plates required to maintain proper airflow in the frame and for Electro Magnetic compliance are installed by Imagine Communications Manufacturing to bloc...

Страница 26: ...16 Imagine Communications Corp Proprietary and Confidential September 2016 Page 26 15 RU Platinum IP3 Rear View Input Back Modules Alarm and Expansion Module Communications Back Panel Rear Fans Output...

Страница 27: ...stallation and Operation Manual Introduction 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 27 28 RU Platinum IP3 Frame Architecture Figure 8 Platinum IP3 28 RU Fram...

Страница 28: ...pecifications Architecture PLATINUM IP3 PLATINUM 28 RU PX FR 28 15 RU PX FR 15 28 RU PT FR 28 15 RU PT FR 15 Dimensions Width 17 5 in 44 5 cm 17 5 in 44 5 cm 17 5 in 44 5 cm 17 5 in 44 5 cm Depth 18 5...

Страница 29: ...8 4 8 4 Monitoring Slots 1 1 4 4 Alarm Slots 1 1 1 1 Streaming Slots NA NA 1 1 Standard Equipment Power Supply 4 2 4 2 Fans Rear Front 6 front 7 rear fans 6 front 4 rear fans 2 fan modules 1 fan modu...

Страница 30: ...t output and crosspoint modules See Module Interconnect PX BP 28 PX BP 15 on page 302 1 1 PX SYNC MI Sync Module Interconnect The Sync and optional redundant sync module are located above the Resource...

Страница 31: ...PX 576x1024 3G 236W 0 1W 236 1W Video Crosspoint 15 RU PX 288x512 3G 110W 0 1W 110 1W Audio Crosspoint PX ATDM64 X28 55W 0 8W 55 8W Front Fan Top 28 RU only PX FRONT FAN TOP 55 2W 0 82W 56 02W Front F...

Страница 32: ...7W PT DACT OB 14 7W PT AECT IB PT AEBT IB 2 4W PT AECT OB PT AEBT OB 6 5W PT DEC IB 13W PT ENC OB 10W Platinum IP3 Power and Temperature Specifications The specifications in this section are for the P...

Страница 33: ...help distribute input signals across multiple frames that are connected using DensiShield cables For example if you route the Inputs of one Frame to a second frame you have twice the original number o...

Страница 34: ...number of outputs if you route to 2 frames you triple the number of outputs Note Matrix expansion does not require the use of the Expansion Setup UI Matrix expansion is configured in the SDNO Database...

Страница 35: ...have cards in Slot 1 and the inputs of the card in F1 Slot 1 can be expanded to F2 Slot 1 via DensiShield cable connecting the two System Expansion System Expansion allows for multiple frames in your...

Страница 36: ...dware Foundry 2 Select Audio Expansion from the Type drop down 3 Select the first frame from the Frame drop down list 4 Select the frame to connect it to from the second Frame drop down list 5 Click t...

Страница 37: ...ng system used for the Platinum IP3 router is a real time embedded operating system that uses an interrupt driven and priority based task scheduling algorithm to control the operations of the Platinum...

Страница 38: ...576x1024 are achieved in 28RU and 288x512 in 15 RU Video Frame expansion is achieved by utilizing the secondary switching capabilities of the output card Expansion enabled output cards transmit the r...

Страница 39: ...8 channel SD HD 3G Input Module with Frame Synchronizer and Demux for Audio TDM 8 BNC inputs PX HSRMX8X OBG Frame Synchronizer and Mux Output Module 8 16 BNC Optical outputs PT FSDMXO IBG 8 channel SD...

Страница 40: ...ing output cards in the primary and expansion frames for inputs to be accessible For cost effective input expansion expansion only output back modules are available The Expansion module serves as the...

Страница 41: ...nd three fiber optical SDI outputs PX SXP 32 6 Two slot Platinum SX Pro with 32 input channels and HDMI outputs and six SDI outputs PX SXP 32 6 O Two slot Platinum SX Pro with 32 input channels six SD...

Страница 42: ...d routing The PX RES module provides the sync processing necessary to determine the switch timing for the frame The control system reports the presence and type of sync signal detected on each of the...

Страница 43: ...HSR8C IBG PM AECT IB PX HSR2C2D IBG PT DEC IB PX HSR1C1D IBG PM DEC IB PT FSDMX IBG PT FSDMXO IBG PT FSDX8C1D IBG PT FSDX8O1D IBG PT HS IB PT HSO PIN IB PT HSO IB PT HSR1D IBG PT HSR2D IBG PT HSR8C1D...

Страница 44: ...SXP 32x6 PX SXP 64x6 PX SXP 16x3 O PX SXP 32x6 O PX SXP 64x6 O PX SXP 16x3 OD PX SXP 32x6 OD PX SXP 64x6 OD PX RES Parameters and Upgrades For details refer the Platinum IP3 Controller User Manual PX...

Страница 45: ...ven in a powered down state a router connected to any communications system must not interfere with that system and therefore must not violate the communications standard RS 232 RS 422 IEEE 802 etc wh...

Страница 46: ...cally connected link LEDs function correctly Rear Ethernet Ports IP Address 1 192 168 100 250 IP Address 2 192 168 101 250 Changing the Default IP Address of the Rear Ethernet Ports Ethernet settings...

Страница 47: ...detects and locks to NTSC PAL analog HD Tri Level or AES signals The control system reports the presence and type of sync signal detected on each of the four inputs These synchronization signals are m...

Страница 48: ...use LTC Bi Directional Port Reserved for future use LEDs The following LEDs are present on the module Power Active Card ENET 1 LED ENET 2 LED 2 Alarm LEDs Table 12 LEDs on the PX RES Resource Module L...

Страница 49: ...redundant PX RES module as this is not indicated via the ENET LEDs for the redundant PX RES module If there is a problem with the physical ENET connection to the redundant PX RES module it won t be a...

Страница 50: ...ions Corp Proprietary and Confidential September 2016 Page 50 Fuses Figure 17 Fuses on the PX RES Resource Module Fuses on the PX RES Resource Module Fuse Name Fuse Type Fuse Rating Part Number F1 Slo...

Страница 51: ...used or supported in the initial release of Platinum IP3 If coaxial XY protocol is required in a system the Imagine Communications EDGE Router Protocol Translator can be used to interface coaxial XY...

Страница 52: ...t to Send RTS 8 Clear to Send RTS 9 Frame Ground Pins 4 and 6 connected internally Pins 7 and 8 connected internally RSS 422 Pin Assignments Table 14 RS 422 Signal Format Pin Assignments Pin Signal Tr...

Страница 53: ...Synchronization parameter is then enabled If the PX RES Synchronization parameter is set to No all the synchronization stops Routes and parameter information of the standby PX RES will remain as is A...

Страница 54: ...Switch triggering supports the use of independent AES NTSC PAL and tri level HD references The following reference types are supported Table 15 Switch Triggering Supported Reference Types 0 Unknown o...

Страница 55: ...0 50P Line 7 The following reference types are supported but need to be manually configured since they are not automatically detected because of the Horizontal and Vertical rates Table 16 Switch Trigg...

Страница 56: ...ailure or missing front fan modules Video crosspoint reaching critical temperature PX RES synchronization failure Power Consumption Table 17 PX RES Power Consumption 24V Power Rail 15W 5V Power Rail 0...

Страница 57: ...and External Power Supply Alarms and GPI Inputs to the IP3 Controller via the Resource Module PX RES and to LEDs and GPI Outputs on the PX ALARM Platinum IP3 frame rear The PX ALARM can control four...

Страница 58: ...a single module PX ALARM and plugged into the rear of the Platinum IP3 frame PX ALARM ATDM Audio TDM Expansion and Alarm Card PX ALARM DATA Data Expansion and Alarm Card The Platinum IP3 frame has tw...

Страница 59: ...um IP3 Controller via the Resource card PX RES and to the GPI Outputs and LEDs Alarm Type Alarm Details Number of Alarms Power Supply Zone Redundancy on page 61 Redundancy by power zone 1 Power Supply...

Страница 60: ...5 16 in zones 1 4 refer to external power supplies PSU 5 6 7 8 13 14 15 16 will show as N A these are for 28 RU frames only In case of a 15 RU frame PSU 1 2 3 4 in zones 1 2 refer to the power supplie...

Страница 61: ...ndancy is reported via the PX ALARM DATA module Note that the UI displays 4 zones even in case of the 15 RU Platinum IP3 frame which has only 2 zones Zones 3 and 4 will show as N A for a 15 RU frame G...

Страница 62: ...ough 4 to the PX ALARM module When a GPI Output is asserted the corresponding GPO LED is lit on the PX ALARM module Figure 20 User Definable Alarms Fan Failure Alarm Rear Fans status is reported via t...

Страница 63: ...tor and clamping diode are connected to each Input to protect the Input from over voltage The GPI Outputs are electrically isolated using a Relay with 3 contacts Access to all 3 contacts of the relay...

Страница 64: ...User defined 2 20 Floating 8 Common User defined 3 21 Remote in 1 9 Normally closed User defined 3 22 GND Common in 1 10 Normally open User defined 3 23 Floating 11 Common User defined 4 24 Remote in...

Страница 65: ...from the power supply RO 0 100Amps PS 24VL Current 24V current is being drawn from the power supply RO 0 100Amps Alarm Alarm External Alarm Enable Enable external alarm Set based on whether the alarm...

Страница 66: ...upply 24V Turns green when either power is present from either Zone 1 or 2 D11 GPI Input 1 Turns red when GPI Input 3 is asserted contact closure to ground There are LED indicators on the Resource Mod...

Страница 67: ...gine Communications Corp Proprietary and Confidential September 2016 Page 67 Power Consumption Table 23 PX ALARM Power Consumption PX ALARM ATDM PX ALARM DATA No Expansion PX ALARM DATA Expansion 24V...

Страница 68: ...module 4 inputs and 4 outputs Table 24 Video Connectors Inputs Outputs Slot IN 1 OUT 1 6 IN 2 OUT 2 6 IN 3 OUT 3 7 IN 4 OUT 4 7 Note The Audio connectors though present are not currently used or func...

Страница 69: ...800mVp p 10 External input amplitude 800mVp p 10 Max input cable length 1694A Up to 150m for 3Gbps Up to 200m for 1 5Gbps Up to 400m for 270Mbps Reclocking Automatic for data rates defined by SMPTE 42...

Страница 70: ...arameters are displayed The total number of modules of that type in the frame is also displayed on the left Parameters Name Description Type Options General Module Status Displays current status of th...

Страница 71: ...ions Corp Proprietary and Confidential September 2016 Page 71 Name Description Type Options TDM RX Input Present Table Parameter Yes No TDM RX CRC Error Clear Table Parameter RW No Yes Audio Reference...

Страница 72: ...x that enables 576x1024 switching within a single Platinum IP3 28 RU frame The PX 288 512 3G Video Crosspoint Module enables 288x512 switching within a single 15 RU frame You can switch any of the 288...

Страница 73: ...tion and Operation Manual Video Crosspoint Module PX 576x1024 3G PX 288x512 3G 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 73 Figure 25 PX 288x512 3G Video Crossp...

Страница 74: ...ber 2016 Page 74 28 RU Video Crosspoint Module Location in the Frame The Platinum IP3 28 RU frame includes two slots for Video Crosspoint modules The First slot holds the Primary Video Crosspoint Modu...

Страница 75: ...Secondary it s important to think of the Crosspoint modules using the Active and Standby notion because those states define the Module that is currently functioning and the one backing it up The Activ...

Страница 76: ...agine Communications Corp Proprietary and Confidential September 2016 Page 76 3 On the upper extractor press the back side of the locking pin while pushing the extractor in 4 After the extractor relea...

Страница 77: ...x512 3G 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 77 6 With the extractor handles horizontal begin sliding the crosspoint module out 7 Gently remove the Crosspo...

Страница 78: ...Proprietary and Confidential September 2016 Page 78 Putting the Video Crosspoint back into the 28 RU Frame Table 27 Putting the Video Crosspoint Module back into the Frame When you need to put the Vid...

Страница 79: ...5 RU Video Crosspoint is similar to the process for the 28 RU with some minor differences The 15 RU Video Crosspoint Module is similar to the 28 RU one but only half of the module is populated and con...

Страница 80: ...tion in the list of Modules and click Open Module Table 28 Video Crosspoint Module Parameters Name Description Type Options Module Status Displays current status of module RO Module Ready Firmware Upg...

Страница 81: ...ED DESCRIPTION POWER Power Supply indicator Green When lit this indicates that 24V is enabled on this board ACT CTRL Active Control Red Initializing Solid Green FPGA has configured and the Resource Mo...

Страница 82: ...576x1024 3G PX 288x512 3G 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 82 Fuses on the Video Crosspoint Module Table 30 Fuses on the Video Crosspoint Module Fuse...

Страница 83: ...ry and Confidential September 2016 Page 83 Power Consumption Table 31 PX 576x1024 3G Power Consumption 24V Power Rail 236W 5V Power Rail 0 1W Total Power 236 1W Modules in Frame 2 Primary and Secondar...

Страница 84: ...o eliminate audible switching artifacts It also allows for certain audio effects for a given destination Platinum and Platinum IP3 Routers support all types of audio including Dolby E and AC3 Since au...

Страница 85: ...ary and Confidential September 2016 Page 85 When incoming audio is embedded within a video source that audio is routed through the Video wideband crosspoint without any processing The embedded audio a...

Страница 86: ...ule PX ATDM64 X28 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 86 Audio TDM Crosspoint Module PX ATDM64 X28 Location in the IP3 Frame Audio TDM Crosspoint 1 2 Modu...

Страница 87: ...become active in case the Primary module is removed or halted due to error The shadow module sets its outputs to a high impedance state until it becomes active but otherwise performs all operations i...

Страница 88: ...tions Corp Proprietary and Confidential September 2016 Page 88 Fuses on the PX ATDM64 X28 Figure 30 Fuses on the PX ATDM64 X28 Table 33 PX ATDM64 X28 Fuses Fuse Name Fuse Type Fuse Rating Present on P...

Страница 89: ...to the ON position After you put the board into Failsafe mode push the Reset button SWC1 or power cycle the board by unplugging plugging the board from the frame Use the Controller s GUI to upgrade t...

Страница 90: ...Corp Proprietary and Confidential September 2016 Page 90 Fans on the Audio TDM Crosspoint Module PX ATDM64 X28 Figure 32 Fans on the PX ATDM64 X28 Table 34 PX ATDM64 X28 Fan Components Fan Component...

Страница 91: ...oard 3 Replace the Fan blower 4 Attach the Fan Connector and wires Sync References The ATDM module requires a PT SYNC module to be installed in the frame for distribution of an internal sync signal wh...

Страница 92: ...als is supported as a predefined transition type Quiet switching is implemented as a v fade of two signals with minimum duration Synchronous Switching AES streams are switched synchronously at the AES...

Страница 93: ...active within one video frame of an error occurring or with removal of the active board The ATDM modules in conjunction with the Resource Module PX RES determine which slot contains the Active module...

Страница 94: ...CRIPTION POWER Power Supply indicator Green When lit this indicates that 24V is enabled on this board ACT CTRL Active Control Red Initializing Solid Green FPGA has configured and the Resource Module P...

Страница 95: ...one frame to another For example to route audio across 2 frames presuming an active and redundant TDM Crosspoint module in each 1 Frame 1 TDM XPT OUT1 Frame 2 TDM XPT IN1 Connect a Densishield cable...

Страница 96: ...n and Operation Manual Audio TDM Crosspoint Module PX ATDM64 X28 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 96 FRAME 1 FRAME 2 PX ALARM ATDM Module PX ALARM ATDM...

Страница 97: ...e the presence Frame Lock and Phase lock of incoming ATDM signals If both frames are properly locked to the same Sync and DARS signals and if the DensiShield cable is properly connected all three LEDs...

Страница 98: ...iption Type Options Module Fans Fan Alarm Table Parameter Indicates if Fan Alarm has been set RO Yes No Fan Running Table Parameter Indicates whether fans are running RO Yes No Module Power Status Ind...

Страница 99: ...8 1 Go to the Firmware Foundry Firmware Repository tab 2 Click the Add Package button 3 Browse and select the firmware upgrade zip and click Open 4 Click OK to the message confirming the firmware will...

Страница 100: ...rp Proprietary and Confidential September 2016 Page 100 8 Click the Select Firmware button at the top 9 In the Select Firmware dialog select the version of the firmware to upgrade the module with Clic...

Страница 101: ...ing the Open Frame link Figure 35 Open Frame option to access Frame parameters The following parameters provide a control interface to the IP3 frame These parameters are divided into different menu gr...

Страница 102: ...escription Options Frame Type RO IP3 28 RU IP3 15 RU Frame ID RO A unique 6 byte frame identifier Ambient Temperature RO The Frame temperature in degrees celsius Figure 36 Frame Parameters PX RES The...

Страница 103: ...ription Options Failsafe PX RES 2 RO Active Standby Not Present Initializing Configuring Failsafe Select Active PX RES RW PX RES1 PX RES2 PX RES Firmware Version RO A string showing the current firmwa...

Страница 104: ...ideo Crosspoint The Video Crosspoint section provides the following parameters Table 39 Video Crosspoint parameters Parameter Type Description Options Video Crosspoint 1 RO Active Standby Not Present...

Страница 105: ...ble 40 TDM Crosspoint parameters Parameter Type Description Options TDM Crosspoint 1 RO Active Standby Not Present Failed TDM Crosspoint 2 RO Active Standby Not Present Failed Select Active TDM Crossp...

Страница 106: ...1920x1080 25P 1920x1080 24P 1920x1080 24PsF 1920x1080 23 97P 1920x1080 23 97PsF 1280x720 60P 1280x720 59 94P 1280x720 50P 1920x1080 60P 1920x1080 59 94P 1920x1080 50P Sync Pulse Delay available only w...

Страница 107: ...ify the video standard to use as the switching point timing reference relative to the sync reference signal detected on the selected Sync input Sync 1 4 If Sync Mode is set to Advanced the Sync Pulse...

Страница 108: ...arameters for a 28 RU Frame Ethernet Ports The Ethernet Ports section provides the following parameters Table 43 Ethernet Ports Parameters Parameter Type Description Options MAC Address 1 RO MAC Addre...

Страница 109: ...RW No Yes MAC Address 2 RO MAC Address of the 2nd Ethernet Port on the active PX RES Port 2 if PX RES on the top slot is active Port 4 if PX RES on the bottom slot is active IP Address 2 RW IP addres...

Страница 110: ...ge 110 Serial Ports The Serial Ports section provides the following parameters Table 44 Serial Ports parameters Parameter Type Description Options Port 1 2 Mode RW RS 232 RS 422 Port 1 2 Baud Rate RW...

Страница 111: ...tes signals to the MI backplane to be switched by the crosspoint matrix PX IB input modules are hot swappable The PX IB accepts an input data stream for each of the nine channels Cable losses are auto...

Страница 112: ...num IP3 frame Each Input Module may be inserted into or extracted from a Platinum IP3 frame while the frame is powered and functioning The system Controller will recognize the addition or removal of a...

Страница 113: ...n page 131 Signal Presence and LEDs Each of the nine input channels on the Input Module provides signal presence reporting via card edge LEDs and the control software Both have the ability to be disab...

Страница 114: ...6 Page 114 LED DESCRIPTION Solid Green FPGA has configured and the control system is communicating with the card Flashing Green Alarm condition on the card ACT IN Active Input Warning Yellow Input on...

Страница 115: ...dules such as PX HSR9O IBG Input Module on page 129 Module Root Level Parameters The following parameters are displayed at the root level when you click the Module in the parameter menu list Table 47...

Страница 116: ...FP OP SFP TT 13 13 OP SFP TT 27 29 OP SFP TT 31 33 OP SFP TT 35 37 OP SFP TT 39 41 OP SFP TT 43 45 OP SFP TT 47 49 OP SFP TT 51 53 OP SFP TT 55 57 OP SFP TT 59 61 NO SFP Input Parameters Input Paramet...

Страница 117: ...80p 23 98 720p 60 720p 59 94 1080p 60 1080p 59 94 1080p 50 1080i 50 295M 720p 50 720p 25 720p 24 720p 23 98 720p 30 720p 29 97 1080p 60 DL 1080p 59 94 DL 1080p 50 DL EQ Bypass Sets the EQ mode RW EQ O...

Страница 118: ...A Input EDH Error EDH error present in input SD signal RO Yes No N A CRC EDH Counter Control Enables or disables the CRC EDH Error Fields counter and the Video Error detector RW Enable Default Disabl...

Страница 119: ...424M SMPTE 292M SMPTE 259M SMPTE 344M DVB ASI Most other 1Vpp digital signals 3Mb s to 3 0Gb s Maximum input level 880mV BNC HD BNC Optical 0dBm typical based on GO2927 2917 Return loss BNC HD BNC 15...

Страница 120: ...modules are hot swappable Each PX OB output module provides a maximum of16 output signal channels Output modules accept 32 signals from the crosspoint matrix Each output channel also contains an outp...

Страница 121: ...and will update the change automatically When the Controller recognizes the addition of an Output Module it allows the user to control the additional inputs to the matrix When inserted into the Plati...

Страница 122: ...tput Module PX HSR8C2DS OBG Output Module PX HSR8O2DS OBG Output Module PX HSR1D2D OBG Output Module on page 137 Signal Presence and LEDs Each of the channels on the Output Module provide signal prese...

Страница 123: ...arning Yellow Output on card being used by one or more outputs Module LEDs See Module LEDs Controllable Parameters For Output Modules the Controllable Parameters List is a multilevel structure that in...

Страница 124: ...Software version of micro controller RO String Control FPGA Version Version of FPGA RO String SFP Type Table Parameter Modules with SFPs only Reports the type of SFP RO Invalid SFP OP SFP TT 13 13 OP...

Страница 125: ...known SD HD 3G Lock Detect Reports if data is relocked by reclocking stage RO Yes No Autobypass RW Yes No Mute Mutes individual board outputs RW Output Enabled Output Muted Enforced Slew Rate Sets out...

Страница 126: ...ength Modules with SFPs only Reports wavelength of fiber optical output RO Specifications Technical Specifications Table 59 Output Module Technical Specifications Item Description Output Connector 75...

Страница 127: ...b s 1 485Gb s 0 2UI reclocked 2 97Gb s 0 3UI reclocked Optical Output Power 2 dBm based on OP SFP TT 13 13 Optical Output Extinction Ratio 7 dB based on OP SFP TT 13 13 Capacity Table 60 PX OB Output...

Страница 128: ...Densishield port for expansion PX HSR1C1D IBG Input Module on page 132 9 Channel Electrical Back Module with 1 HDBNC connector and 1 Densishield port for expansion DIGITAL VIDEO OUTPUT MODULES PX HSR1...

Страница 129: ...n Table 61 PX HSR9C IBG Power Consumption 24V Power Rail 10 7W 5V Power Rail 0 43W Total Power 11 13W PX HSR9O IBG Input Module The PX HSR9O IBG is a 9 channel SD HD 3G Digital Video Input Module with...

Страница 130: ...onsumption 24V Power Rail 14W 5V Power Rail 0 43W Total Power 14 43W PX HSR9C IBG PX HSR9O IBG Parametric Control The PX HSR9C IBG PX HSR9O IBG Module can be controlled via the Controller When you acc...

Страница 131: ...le Power Consumption Table 63 PX HSR9C1D IBG Power Consumption 24V Power Rail 13W 5V Power Rail 0 43W Total Power 13 43W PX HSR9O1D IBG Input Module The PX HSR9O1D IBG is a 9 channel SD HD 3G Digital...

Страница 132: ...nnel SD HD 3G Digital Video Input Module with one HDBNC connector and one DensiShield port for expansion Figure 50 PX HSR1C1D IBG Via the DensiShield port you can receive up to 8 outputs from another...

Страница 133: ...16 channel SD HD 3G Digital Video Output Module with 16 HDBNC connectors Figure 51 PX HSR16C OBG This Back Module interfaces with the PX OB Output module to output16 electrical outputs See Output Mod...

Страница 134: ...es with the PX OB Output module to output up to 16 optical outputs See Output Modules PX OB see Input Modules PX IB on page 111 for details on the PX OB Output module Power Consumption Table 67 PX HSR...

Страница 135: ...of the back module each containing 2 channels There are 2 DensiShield ports on the module one of them accepts up to 8 electrical inputs and the other can output op to 8 electrical outputs The DensiSh...

Страница 136: ...mounted on the metal back panel of the back module There are 2 DensiShield ports on the module one of them accepts up to 8 electrical inputs and the other can output up to 8 electrical outputs The Den...

Страница 137: ...SR8C2D OBG PX HSR8O2S OBG Module can be controlled via the Controller When you access a module by clicking on it in the list of Output Modules its parameters are displayed The total number of PX HSR8C...

Страница 138: ...r 2 DensiShield ports which are intended for expansion However if expansion is not used then the DensiShield output port can be connected to another PX UCIP module Power Consumption Table 70 PX HSR1D2...

Страница 139: ...rietary and Confidential September 2016 Page 139 PX UCIP Uncompressed Video over IP Modules See the standalone PX UCIP Module User Manual for more details You can download this manual from the Resourc...

Страница 140: ...t Boards add Video and Audio processing to input boards in the IP3 Frame The PT FSDMX IBG back module provides BNC connectors The PT FSDMXO IBG back module provides optical inputs through SFP fiber op...

Страница 141: ...odule PT FSDXM IBG See Electrical BNC Back Module PT FSDMX IBG on page 142 8 BNC Connectors Optical Back Module PT FSDMXO IBG See Optical SFP Back Module PT FSDMXO IBG on page 142 8 Fiber Connectors 4...

Страница 142: ...Communications Corp Proprietary and Confidential September 2016 Page 142 Electrical BNC Back Module PT FSDMX IBG Figure 61 PT FSDMX IBG electrical back module Figure 62 PT FSDMX IBG electrical back m...

Страница 143: ...Electrical Back Module HD BNC with DensiShield PT FSDX8C1D IBG The PT FSDX8C1D IBG Input module is based on the PT FSDMX IBG module and it provides 8 input SDI options via HD BNC connectors In additio...

Страница 144: ...r This input module enables video matrix expansion Figure 67 PT FSDX8O1D IBG Back Module Figure 68 PT FSDX8O1D IBG Back Module Specifications PT FSDMX IBG PT FSDMXO IBG PT FSDX8C1D IBG PT FSDX8COD IBG...

Страница 145: ...1080p SMPTE296M 720p Return loss 18 dB typical from 5 MHz to 1485 MHz Equalization Adaptive cable equalization for up to 590 ft 180 m typical of Belden 1694A co axial cable HD SDI 3Gb s SMPTE 424M For...

Страница 146: ...d Detection Insertion HD and 3G only EDH SD and CRC HD Detection Insertion Automatic ASI detection and bypass Bypass mode no Video Audio processing Video Processing Notes VANC HANC Data other than emb...

Страница 147: ...eam See Quiet Audio Transitions on page 148 Audio Processing Notes and Restrictions De embedding For De embedding audio must be embedded synchronously at a sample rate of 48kHz Embedded Dolby E frames...

Страница 148: ...g by an upstream router These transitions work independent of whether the two sources are synchronous or asynchronous to each other or with respect to the reference signal and it works regardless of...

Страница 149: ...lowing modes Framesync mode SDI channels are genlocked to a common reference source which can be either NTSC PAL or TriLevel Your video reference has to be the same frame rate as your input The input...

Страница 150: ...t Parameters on page 151 General Parameters Table 71 PT FSDMX IBG General Parameters Name Description Type Options General Info Temperature x 2 TABLE PARAMETER Indicates the temperature of the FPGA RO...

Страница 151: ...Reports the presence of the reference video signal RO No Yes Genlock Video Locked Reports the locked status of the reference video signal RO No Yes Genlock Standard Indicates the video standard detec...

Страница 152: ...Reports the number of chrominance CRC EDH errors that have occurred RO 0 to 65535 CRC EDH Error Clear x 8 Clears all CRC EDH error counters RW No Yes Input Optical Power Optical modules only Reports...

Страница 153: ...ts the sampling rate from the control packet of the specified audio group RO 48 0 kHz 44 1 kHz 32 0 kHz N A FreeRun DeEmbed Control Specifies the operation of the audio de embedder when an error occur...

Страница 154: ...le B Summing x 8 Specifies whether to sum the audio within a pair Left to Right the summed audio is placed in the right channel Right to Left the summed audio is placed in the left channel Both the su...

Страница 155: ...ndard RW 0 000 us to 29 616 us 1080p 30 1035i 60 0 000 us to 14 808 us 1080p 60 1080p 60 DL 0 000 us to 29 646 us 1080p 29 1080i 59 0 000 us to 14 823 us 1080p 59 1080p 59 94 DL 0 000 us to 35 542 us...

Страница 156: ...hen a channel is operated in Framesync mode or if a board without a Framesync license Demux only has the ingested SDI signal already locked to the reference signal applied to the board the Audio Embed...

Страница 157: ...o allow the flexibility for users to steer the word length of the re embedded Audio data such that it matches the word length of Audio data that originates from a different source for example Audio re...

Страница 158: ...98 1080p 23 98 1080sF 23 98 In both Sync mode and Delay mode PT FSDMX provides several controls to manipulate the output video signal Horizontal timing Vertical timing Adjustable frame delay Manually...

Страница 159: ...de embedding error the de embedder mutes the current outgoing AES sample Audio Test Tones The following table describes the frequency and levels of each audio output test tone available as a selection...

Страница 160: ...nnel Status Ch 1 8 Red Power on test failed FPGA Temp FPGA Temp A B Red Above temperature limit Power Up sequence Due to the complexity of the board and its parameter list it takes about 2 5 minutes a...

Страница 161: ...BG modules takes approximately 50 minutes Multiple identical boards can be upgraded at once in batches of up to 16 boards one zone A batch upgrade takes about as long as upgrading a single board Alway...

Страница 162: ...dependently with support for SD 1 5 Gb s HD 3 Gb s HD and 3 Gb s Dual Link formats ASI signals are reported and processing stages are automatically bypassed Both full Framesync and Delay modes are ava...

Страница 163: ...ry and Confidential September 2016 Page 163 PX HSR8CMX8C OBG Electrical Output Module Figure 70 HSR8CMX8C OBG Electrical Back Module PX HSR8OMX8O OBG Optical Output Module Figure 71 PX HSR8OMX8O OBG O...

Страница 164: ...ield frame rates need to match those of the applied Reference In the Frame Sync Mux Mode menu the following modes of operation can be selected on a per SDI channel basis MUX Auto Detect Note MUX Auto...

Страница 165: ...e the Frame Sync license this feature will not be available To acquire a Frame Sync license contact your Customer Service representative A license can be added for the module using the License Key par...

Страница 166: ...atch Frame Sync Delay Mode Note In Delay mode only a restricted set of processing features can be applied to an SDI channel When operating the Frame Sync in Delay mode the audio embedders are automati...

Страница 167: ...FS Audio Delay FS MUX FS MUX Audio ProcAmp FS MUX FS MUX Dolby E Header Alignment FS MUX FS Framesync Mode with Framesync License DLY Delay Mode with Framesync License MUX Mux only Operation without F...

Страница 168: ...om the Audio crosspoint via TDM are assumed to have a 48kHz sample rate and locked to the same Video reference applied to the board Automatic Dolby E header alignment supported for Dolby E data receiv...

Страница 169: ...ported with 16 mono channels of Audio processed Processed Video Audio data exits the board as a single 3Gb s stream Non PCM Audio data Dolby E or Dolby D is not processed by the Audio Synchronizer Aud...

Страница 170: ...tor Amphenol HD BNC Impedance 75 ohms ASI 270 Mb s SD SDI 270 Mb s SMPTE 259M Format 525i59 94 625i50 Return Loss 15 dB from 5 MHz to 270 MHz HD SDI 1 5 Gb s SMPTE 292M Format and Image Sample Structu...

Страница 171: ...mplitude 800 mV differenial Supported Cable Type FCI 10116746 R0600BULF Supported Cable Length 6m Formats ASI SD SDI HD SDI 3G SDI Note Gennum is the supported SFP for all Platinum Framesync Optical M...

Страница 172: ...pgrade the upgraded board s will automatically reboot and will start unpacking the newly installed firmware components This process can take up to 2 minutes and should not be interrupted In case the b...

Страница 173: ...r Serializer Bypass Mux for ASI SDI Out to Cable Driver or SFP Tx PT HSRMX OBG PX HSRMX OBG Data Flow firmware version 2 1 or higher Video Frame Synchronizer DDR2 Memory Video ProcAmp Clock Transfer F...

Страница 174: ...ameters are displayed The total number of modules of that type in the frame is also displayed on the left General Parameters Name Description Type Options Physical Info Temperature TABLE PARAMETER Ind...

Страница 175: ...e components RO String Module Status Reports current Module Status RO Module Ready Firmware Upgrade Required Module Over Temperature Genlock Parameters Name Description Type Options Sync Select Select...

Страница 176: ...W Yes No Dolby E Auto Align RW Yes No Video Name Description Type Options Processed Outputs Video SDI Video Standard Displays the SDI video signal standard RO Unknown 525i 59 94 625i 50 720p 25 720p 2...

Страница 177: ...r counters RW No Yes Output Mute Enables Disables electrical BNC output RW No Yes Dolby E Detection Allows Dolby E detection based on presence of Dolby E Header Can be used with or without PCM non PCM...

Страница 178: ...l be embedded into the outgoing SDI stream Disconnected Stereo pairs will be automatically replaced by whatever has been de embedded from the incoming SDI stream RW Yes No ADS Clean Enables and disabl...

Страница 179: ...the last audio sample or mute when an error occurs See DeEmbed Control on page 185 RW Mute Repeat Embedding Mode Selects the embedding mode for the specified audio group RW Off Append OverWrite Auto...

Страница 180: ...Audio Rd Wr pointers in the Audio Synchronizer affecting all eight Stereo pairs of the selected SDI channel will be reset RW Reset Toggle A Reset Toggle B Summing Specifies whether to sum the audio wi...

Страница 181: ...s offset for the Y channel RW 100 6 mV 0 mV in 0 8 mV increments Cb Offset mV Adjusts offset for the Cb channel RW 100 6 mV 0 mV in 0 8 mV increments Cr Offset mV Adjusts offset for the Cr channel RW...

Страница 182: ...to 17 771 us 1080p 50 1080p 50 DL 0 000 us to 37 024 us 1080p 24 1080sF 24 0 000 us to 37 061 us 1080p 23 98 1080sF 23 98 0 000 us to 31 987 us 1080i 50_295 0 000 us to 22 209 us 720p 60 0 000 us to...

Страница 183: ...Video Frame Synchronization on page 189 RW FS Sync Mode FS Delay Mode Mux Auto Detect Mux Always On Bypass Frame Sync Mux Status Reflects operational mode status based on license mode of operation pre...

Страница 184: ...rd length of 24 bits When the processed audio data word length is 20 bits determined by parameter Word Length parameter the Audio Embedder cannot overwrite existing extended Audio packets There are 2...

Страница 185: ...at type of Audio linear PCM or non PCM it is dealing with in order to not to destroy Dolby E data for instance by the sample rate conversion process linear PCM data would normally undergo Based on the...

Страница 186: ...he same audio group number failing that it appends the new audio data and control packets immediately following the last existing audio data control packet refer to the Audio Group 1 4 Exists paramete...

Страница 187: ...exists in the ancillary data space no audio will be embedded Figure 77 Append Embedding Mode Adding Group 1 and a Group 1 Already Exists If you insert Group 2 audio when there is pre existing Group 1...

Страница 188: ...empts to overwrite any existing audio data and control packets of the same group number with the new audio data This setting is valid only if the audio group to be embedded already exists If the new s...

Страница 189: ...delay Additionally up to three seconds of delay can be added through the Channel Delay parameter Video Frame Synchronization The Frame synchronizer offers two modes Delay mode and Synchronizer Sync m...

Страница 190: ...20p 50 625i 50 1080p 50 DL 720p 59 94 720p 59 94 1080p 59 94 1080p 24 1080sF 24 1080p 24 1080sF 24 720p 50 720p 50 1080p 50 1080p 23 98 1080sF 23 98 1080p 23 98 1080sF 23 98 In both Sync mode and Dela...

Страница 191: ...udio industry especially in the professional sector Its advantages over other audio digital interface protocols and standards are support of a greater number of channels per line MADI support enables...

Страница 192: ...G input module is an AES10 2008 compliant audio input board that supports three MADI formats 32 channel 96kHz sample rate and 56 or 64 channels 48 kHz sample rate The PT MADI4X IBG is user configurabl...

Страница 193: ...ectrical Back Module The electrical back module is an active back module attached to the front module with two brackets and with Cable Equalizers The back module has four BNC connectors and stays atta...

Страница 194: ...ages will be used The back module has to be mounted onto the frame and the Front Module detaches from the Back Module when the Front Module is pulled out from the frame One Dual Rx SFP module is pre i...

Страница 195: ...are reported as active or not TDM Mapping Through the PT MADI4X IBG parameter interface channels in MADI inputs can be manually mapped to the TDM stream and you can select if one or all of the MADI i...

Страница 196: ...signal Channels within input signal are passed The uppermost 32 TDM channels are muted and inactive 56 channel input 32 channels 32 channels allocated on the TDM bus for the MADI signal Channels 1 th...

Страница 197: ...our 64 channel MADI Inputs 1 and 3 mapped In this example all MADI inputs are 64 channel Since a total of 128 channels mappings are allowed a maximum of two inputs can be mapped to the TDM Inputs from...

Страница 198: ...n the Controller UI Open up the MADI Input Module Go to Mapping in the navigation tree Set all MADI Input 3 to 32 and MADI Input 4 to 56 in the MADI to TDM Map MADI Audio Formats MADI sources and or d...

Страница 199: ...using the Multiplex Stereo Audio Device Type the Audio channel must be kept at Audio 1 while incrementing the Port number between Left and Right audio channels For example for stereo audio channel 1 e...

Страница 200: ...ength Wideband 1250nm 1380nm Receiver Sensitivity 30dBm PIN Receiver Link rate 125Mbit s 4B5B encoded NRZI Qualified devices Optoway SPM 3102W 2RG PT MADI4C IBG Specifications Table 83 Electrical Inpu...

Страница 201: ...nique identifier String Temperature RO FPGA V6 temperature String in degrees celsius Parameter Hysteresis R W Parameter updated time Integer 2000000 us Software Version RO Embedded software version St...

Страница 202: ...Channel MADI 1 4 01 16 R Bit map for each active channel String MADI 1 4 17 32 R Bit map for each active channel String MADI 1 4 33 48 R Bit map for each active channel String MADI 1 4 49 64 R Bit map...

Страница 203: ...he TDM Receiver The PT MADI4X OBG output module can encode up to128 TDM audio channels into up to 4 MADI outputs with each output capable of up to 64 channels each or 32 AES stereo pairs of PCM Audio...

Страница 204: ...orm factor Pluggable SFP Fiber Optic Modules Rx or Tx Only two of the four cages will be used The back module has to be mounted onto the Platinum frame and the Front Module detaches from the Back Modu...

Страница 205: ...ut Module through the Controller You can access and control PT MADI4x OBG parameters through the Controller by selecting it in the list of Output Modules and then clicking Open Module Reference Lockin...

Страница 206: ...I transport stream Using a separate non TDM reference for MADI If the reference signal for MADI is different than the one used for TDM locking channels conveying non PCM data such as Dolby E D are des...

Страница 207: ...ons TDM MADI Any of the supported DARS Ref Rates Same as TDM Ref DARS Ref Any of the supported DARS Ref Rates Any of the supported DARS Ref Rates can be unrelated and asynchronous to TDM DARS Ref Any...

Страница 208: ...Optoway SPM 3102W 2TG Laser Safety Class 1 Laser Product Output Power Consumption PT MADI4O OBG Power Consumption Table 89 PT MADI4O OBG Power Consumption Power Consumption 25W includes front module...

Страница 209: ...Wavelength 1 4 Table Parameter RO Reports wavelength of fiber optical output N A 1300 Laser Status 1 4 Table Parameter RO Reports laser status Enabled Disabled N A Normal Failed Laser Enable 1 4 Table...

Страница 210: ...ith the PT MADIxx OBG since the output sample rate is always 48kHz Unknown 525i 59 94 625i 50 720p 25 720p 29 97 720p 30 720p 50 720p 59 94 720p 60 1080p 23 98 1080p 24 1080p 29 97 1080p 30 1080p 25 1...

Страница 211: ...0p 59 94 720p 60 1080p 23 98 1080p 24 1080p 29 97 1080p 30 1080p 25 1080i 50 1080i 59 94 1080i 60 1080sF 23 98 1080sF 24 DARS 192kHz DARS 96kHz DARS 88 2kHz DARS 48kHz DARS 44 1kHz DARS 32kHz TDM Inpu...

Страница 212: ...sion Multiplexing architecture To reduce idle channel noise in systems using A D and D A converters audio level sensing circuitry is included that will mute the output i e set all sample data 0 when t...

Страница 213: ...put signals are received by high quality audio line receivers containing internal laser trimmed matched resistors for maximum common mode rejection The signals are converted from balanced to single en...

Страница 214: ...a row on the front of the input module Each of these LEDs illuminates when a signal on the input exceeds the maximum input amplitude or level adjust available through TDM scales the digital signal be...

Страница 215: ...d time duration before muting is released providing hysteresis to this function The second implementation of analog level detection is performed in the A D converter When the analog level exceeds the...

Страница 216: ...setting for analog to digital conversion RW 13 dB to 28 dB in 1 dB increments Presence Hysteresis 1 16 Sets the time duration between acquisition of signal presence and release of audio muting RW 7 5...

Страница 217: ...f a signal on Channel A RO No Yes Ch B Presence 1 16 Reports absence or presence of a signal on Channel B RO No Yes Phase Alarm 1 16 Alarm set if left and right channels are out of phase RO No Yes Cli...

Страница 218: ...peration Manual Analog Digital Audio Converter Modules with TDM 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 218 Functional Block Diagram Figure 96 PM ADCT IB PT A...

Страница 219: ...5B Gnd 35 9B Gnd 42 13B Gnd 35 2A 14 6A 6 10A 14 14A 6 2A 13 6A 5 10A 13 14A 5 2A Gnd 29 6B 34 10A Gnd 29 14B 34 2B 41 6B 19 10B 41 14B 19 2B 26 6B 7A Gnd 20 10B 26 14B 15A Gnd 20 2B Gnd 40 7A 4 10B...

Страница 220: ...2 kHz 44 1 kHz 48 kHz 88 2 kHz 96 kHz or 192 kHz using internal oscillators Gain stability 0 01 dB Frequency response 0 15 dB 20 Hz to 20 kHz Linearity deviation 0 5 dB typical 1 0 dB worst case THD N...

Страница 221: ...32 kHz 192 kHz using external AES reference 32 kHz 44 1 kHz 48 kHz 88 2 kHz 96 kHz or 192 kHz using internal oscillators Gain stability 0 01 dB Frequency response 0 15 dB 20 Hz to 20 kHz Linearity dev...

Страница 222: ...put Modules with TDM Capability PT DACT OB Operation Figure 97 PT DACT OB Module The PT DACT OB audio D A output module provides the platform for AES digital to analog audio conversion within the Plat...

Страница 223: ...al block adapter is available to accommodate wiring of individual signals to the frame Figure 98 PT A2 DTB Terminal Block Adapter Installation All output modules and back panel modules are installed a...

Страница 224: ...d left channels are out of phase RO Yes No Clip Detect 1 16 Reports if signal on the input exceeds the maximum input amplitude RO Yes No Audio Mute 1 16 Sets mute for any data passing reclocking stage...

Страница 225: ...Options Module Audio Reference Selects AES reference input for source RW Sync 1 Sync 2 Sync 3 Sync 4 Parameter Hysteresis Sets hysteresis for parameters needing it RW 0 to 5 seconds in 500 ns steps S...

Страница 226: ...peration Manual Analog Digital Audio Converter Modules with TDM 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 226 Functional Block Diagram Figure 99 PM DACT OB PT D...

Страница 227: ...2 9A Gnd 44 13A 14A Gnd 22 1B 43 5B 36 9B 43 13B 36 1B 28 5B 21 9B 28 13B 21 1B Gnd 42 5B Gnd 35 9B Gnd 42 13B Gnd 35 2A 14 6A 6 10A 14 14A 6 2A 13 6A 5 10A 13 14A 5 2A Gnd 29 6B 34 10A Gnd 29 14B 34...

Страница 228: ...tment range 0 dBFS 13 dBu to 28 dBu in 1 dB steps 0 5 dB DC offset 0V 0 05V Conversion type 128x oversampling fifth order delta sigma Resolution 24 bits AES frame rates 32 kHz 192 kHz Gain stability 0...

Страница 229: ...rsion type 128x oversampling fifth order delta sigma Resolution 24 bits AES frame rates 32 kHz 192 kHz Gain stability 0 01 dB Frequency response 0 25 dB 20 Hz to 20 kHz Linearity deviation 0 5 dB THD...

Страница 230: ...es with TDM Capability 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 230 AES Balanced Coaxial Modules with TDM Capability AES Balanced Coaxial Input Modules with TD...

Страница 231: ...odule provides a TDM version of all input signals to be distributed to the audio specific crosspoint module or optionally it can pass the first eight AES inputs to the wideband crosspoint It allows fo...

Страница 232: ...modules To provide the required BNC interface the PT AEC BOC must be used in conjunction with the PT AEC IBP for connection to coaxial cables Figure 102 PT AEC BOC Cables Installation Input Module Ins...

Страница 233: ...ble Parameter R W Indicates type of tone to send out AES output Pass Input Silence 500 Hz 1 KHz Polarity Reversal 1 32 Table Parameter R W Reverses and to correct audio polarity in the analog domain N...

Страница 234: ...R W Description Options Summing 1 16 Table Parameter R W Add left and right audio samples divide by 2 NOTE This parameter is always applied before swap copy None Right to Left Left to Right Both Out...

Страница 235: ...PT AEBT IB Pinout Information J2 Inputs 1 8 DB 25 Pin No J1 Inputs 9 16 DB 25 Pin No 1 13 9 13 1 12 9 12 1 Gnd 25 9 Gnd 25 2 24 10 24 2 23 10 23 2 Gnd 11 10 Gnd 11 3 10 11 10 3 9 11 9 3 Gnd 22 11 Gnd...

Страница 236: ...mpedance 110 Signal type AES3 AES frame rates 32 kHz to 192 kHz Other 40 60 duty cycle digital signals from 2 Mb s to 25 Mb s Input amplitude 0 2 Vpp 7 Vp p Nominal input amplitude 5 Vp p 1 V AES Coax...

Страница 237: ...2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 237 Power Consumption Table 105 PT AECT IB PT AEBT IB Power Consumption Power Consumption 2 4W AES Balanced Coaxial O...

Страница 238: ...g either a balanced or coaxial back module within the Platinum platform and supports Time Division Multiplexed TDM AES routing Audio processing functions as well as signal level conversion and presenc...

Страница 239: ...ules To provide the required BNC interface the PT AEC BOC must be used in conjunction with the PT AEC OBP for connection to coaxial cables Figure 106 PT AEC BOC Cables Installation Output Module Insta...

Страница 240: ...KHz Polarity Reversal 1 32 R W Reverses and to correct audio polarity in the analog domain Normal Invert Crosspoint Type R W Determines crosspoint matrix requirement TDM Wideband Disconnect State R W...

Страница 241: ...uration Shortest Short Medium Short Medium Medium Long Long Longest Functional Block Diagram Monitor 16 AES output 16 FPGA based signal presence detection and internal distribution On board supply Con...

Страница 242: ...19 6 18 6 17 7S 16 8 15 8 14 1 13 1 12 2S 11 3 10 3 9 4S 8 5 7 5 6 6S 5 7 4 7 3 8S 2 Spare 1 1S 25 2 24 2 23 3S 22 4 21 4 20 5S 19 6 18 6 17 7S 16 8 15 8 14 J2 Outputs 1 8 DB 25 Pin No J1 Outputs 9 16...

Страница 243: ...kHz Other 40 60 duty cycle digital signals from 2 Mb s to 25 Mb s Jitter 5ns Output amplitude 5 Vp p 1 V into 110 load DC offset 0 V 0 05 V Rise fall times 5 ns 30 ns Propagation delay 170 ns Table 1...

Страница 244: ...ion Manual AES Balanced Coaxial Modules with TDM Capability 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 244 Power Consumption Table 110 PT AECT OB PT AEBT OB Powe...

Страница 245: ...g to analog video routing with the optional PM ENC OB or PT ENC OB encoder output module Hardware Reporting Each of the eight channels will provide standard reporting of signal presence using a card e...

Страница 246: ...emodulation process a color space converter is used to convert the red and blue color components to U and V color difference components Cr Cb as needed for ITU R 601i and SMPTE 125M type signals The R...

Страница 247: ...corresponds to the PT DEC IB module Installation Input Module Installation All input modules are installed at our manufacturing facility If you need to purchase additional components please contact y...

Страница 248: ...Filters Brightness 1 8 Table Parameter R W Sets brightness level 0 255 128 Contrast 1 8 Table Parameter R W Sets contrast level 0 255 128 Chrominance Saturation 1 8 Table Parameter R W Sets chrominan...

Страница 249: ...nals Power from frame Control Logic On board supply ENET 5 V 5 V Card health and signal presence LEDs 3 3 V 24VA 24VB 1 8 V 1 5 V Local I2C Local I2C Power failure monitoring PIPE 2 5 V Figure 109 PT...

Страница 250: ...nsumption Power Consumption 13W SD to Analog Video Encoder Modules PT ENC OB Operation The PT ENC OB is a SD to analog video encoder output module that converts a block of eight serial SD digital sign...

Страница 251: ...internal test signal generator chrominance level and hue NTSC only brightness sharpness and digital noise reduction You must be careful when implementing the notch and low pass filters as a tradeoff...

Страница 252: ...is for parameters needing it 0 to 5 seconds in 500 ns steps Sync Type R W Selects which physical sync port the module uses as a reference Sync1 Sync2 Sync3 Sync4 Out Video Standard 1 8 Table Parameter...

Страница 253: ...o Modules 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 253 Parameter RW Description Options Table Parameter Lock Detect 1 8 Table Parameter R W Reports presence or...

Страница 254: ...allation and Operation Manual Analog Composite Video Modules 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 254 Functional Block Diagram Figure 110 PT ENC OB Functio...

Страница 255: ...ions Item Specification Number of outputs 8 Output connector 75 BNC per IEC 169 8 Impedance 75 Signal type NTSC PAL Output amplitude 1 0Vp p 10 Return loss 40 dB DC to 5 75 MHz Filtering CCIR 601 comp...

Страница 256: ...ntrol over VNC and advanced graphical processing capabilities Figure 111 Platinum SX Hybrid Output Module The output module occupies four slots in the output section of any Platinum IP3 frame It is a...

Страница 257: ...e module only handles 1 5G signals when used in an IP3 frame Video inputs are routed from the router s crosspoint modules to the inputs of the output module The module receives up to 32 baseband video...

Страница 258: ...the size of the router frame This table lists the number of supported output modules that can be installed in 15RU and 28RU Platinum IP3 router frames Table 117 Number of Installed Output Modules in P...

Страница 259: ...module 512 per frame 1024 per frame Platinum SX Hybrid Back Module The multiviewer s back module is connected to the rear of the router frame and provides connectors for output video signals communic...

Страница 260: ...nsure you properly align the module with the appropriate guide notches in the router frame Failure to do so may damage the pin connections between the back and output modules Output modules can be ins...

Страница 261: ...ull and hold the back module s extractor handle and then slide the back module assembly into the frame until it is fully seated 5 Let go of the extractor handle and push it into the locking position 6...

Страница 262: ...eration Manual Platinum SX Pro Multiviewer Modules 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 262 Platinum SX Pro Multiviewer Modules Please refer to the Platinu...

Страница 263: ...PS on page 265 for information on the optional Power Supply Frames See Power Distribution Modules on page 277 for information on Power Distribution Modules that interface between the power supplies an...

Страница 264: ...wer into the frame In ON mode the power supply is supplying power to frame Once an AC power cord is attached to a power supply its becomes energized partially operational internally Power Supplies in...

Страница 265: ...ed separately See Installing Power Supplies on page 270 The PX FR EXPS External Power Supply Frame is connected to the PX FR 28 or PX FR 15 IP3 frame using four DC power cables 165 100036Q00 24 or 165...

Страница 266: ...nation D Sub 165 100036Q00 Standard length cable that connects the PX FR 28 PX FR 15 Frame to the PX FR EXPS Note Four 24 cables are included when you buy the PX FR EXPS frame 24 cables are recommende...

Страница 267: ...en connectors with gold contacts on the Rear panel One is rotated 180 degrees from the other Keep this in mind when attaching the Interface DC power cables Figure 115 Rear View of the PX FR 28 frame s...

Страница 268: ...ply and External Power Supply Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 268 3 Attach the Interface DC power cables between the PX FR 28 and PX FR EXPS Fig...

Страница 269: ...onnector by tightening the screws Figure 118 Locking Screws to secure DC Power Cables connected to PX FR 28 The following figure shows the 90 DC power cables attached to the bottom of the PX FR 28 fra...

Страница 270: ...frame This prevents damage to the frame and latch Figure 120 Power Supply with Latch in Unlocked Position To install a Power Supply 1 Align a Power Supply PX PS with the slot on the Frame 2 Gently sli...

Страница 271: ...att Power Supply and External Power Supply Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 271 Tighten the thumbscrew turn clockwise to lock the latch in place...

Страница 272: ...0 Watt Power Supply and External Power Supply Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 272 Power Zones Power Zones for a 28 RU Frame In a 28 RU frame pow...

Страница 273: ...Platinum IP3 Installation and Operation Manual 1500 Watt Power Supply and External Power Supply Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 273...

Страница 274: ...ual 1500 Watt Power Supply and External Power Supply Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 274 Power Zones for a 15 RU Frame In a 15 RU frame power di...

Страница 275: ...Frame PX FR 15 is divided into two Zones For low power modules such as the PX HSR9C IBG or PX HSR16C OBG 2N redundancy can be achieved with a second PX PS plugged into a Power Zone For high power modu...

Страница 276: ...COMPONENT ZONE 1 ZONE 2 ZONE 1 ZONE 2 ZONE 3 ZONE 4 Video Crosspoint 1 Video Crosspoint 2 ATDM Crosspoint 1 ATDM Crosspoint 2 Front Fan Module Top Single Front Fan Module Front Fan Module Bottom Rear...

Страница 277: ...connectors and wiring Top Power Distribution Module PX PD TOP The Top Power Distribution Module PX PD TOP is used both in the PX FR 28 PX FR 15 IP3 frames and in the PX FR EXPS External Power Supply F...

Страница 278: ...y Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 278 When the PX PD TOP is used in the IP3 frame switch positions should be set to OPEN OFF Figure 124 Dip Swit...

Страница 279: ...Watt Power Supply and External Power Supply Frame 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 279 Figure 125 Dip Switches SW3 and SW4 on the PX PD TOP when insta...

Страница 280: ...80 Fuses on the PX PD TOP Figure 126 Fuses on the PX PD TOP Table 120 PX PD TOP Fuse Ratings Fuse Type Fuse Rating Part Number Fastblow 10 Amps 127 100013Q00 Bottom Power Distribution Module PX PD BOT...

Страница 281: ...pecification Table 122 Power Supply Mechanical Specifications Item Specification Dimensions 4 5 Inches by 2 6 Inches by 10 25 Inches Cooling Forced Air Cooled Front to Back Airflow Variable Fan Speed...

Страница 282: ...ise 100mV P P 20Mhz Bandwidth Measured across 0 1uF and 10 uF capacitors connected in parallel Overcurrent Protection Non destructively limit current to 110 rated maximum output Square Current Limit w...

Страница 283: ...ly possible when AC power is supplied and power switch is on Flashing RED at 2 Hz Fault condition on secondary is detected 24V OFF Power switch is off or AC power is not present Solid GREEN Correspond...

Страница 284: ...4A Green 24V Return 6 10A 10mA I2C Orange CLK 8 10A 4A 5 Red 5V Supply 9 10A 10mA 24 A Fail C Green Opto Collector 10 10A 10mA 24 A Fail E Purple Opto Emitter 12 10A 10mA 5 Fail C Blue Opto Collector...

Страница 285: ...vide the main cooling for the entire frame power supplies and modules Front Fan Module The PX FRONT FAN module is hot swappable and its main function is to cool the IP3 Video Crosspoint Each PX FRONT...

Страница 286: ...individual front fans with status LEDs Top Front Fan Module Bottom Front Fan Module Six individual front fans with status LEDs Top front fan module status LEDs Bottom front fan module status LEDs Six...

Страница 287: ...ware on the Front Fan module Front Fan LEDs Table 126 28 RU Front Fan Module LEDs LED Name LED Color Description Alarm Level Power Red The 24 VDC power supply is missing Major Green The module is rece...

Страница 288: ...range Video Crosspoint 1 Active Info Green Video Crosspoint 2 Active Info Off Both Crosspoints Inactive Info Fan Module Status Red The Front Fan module is not communicating with the resource module Ma...

Страница 289: ...ainst PX FRONT FAN Figure 132 Front Fan Status for a 15 RU Frame Status is displayed for all 6 front fans you can view Fan Speed and Fan Failure status Rear Fan Module The 28 RU Platinum IP3 has 7 ind...

Страница 290: ...Installation and Operation Manual PX FRONT FAN and PX REAR FAN Modules 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 290 Figure 133 28 RU Front Fans Figure 134 15...

Страница 291: ...ns A 15 RU frame displays status for its 4 rear fans and Fans 5 6 7 will show as N A You can see individual fan speed as well as whether any of the fans have failed Figure 135 Rear Fan Status for a 15...

Страница 292: ...nfidential September 2016 Page 292 3 Disconnect the wiring harness by squeezing the white connector tabs together and gently pulling apart the connector Figure 137 Unlocking Wire Connector 4 Lift the...

Страница 293: ...s 9 Close the other fan array module Replacing an Individual Front Fan To replace an individual front fan follow these steps 1 Open the front door of the frame and locate the faulty fan indicated by a...

Страница 294: ...To remove and replace a Rear Fan Module follow these steps 1 Remove the four captive screws in the corners of the fan unit Figure 141 Rear Fan 2 Carefully slide the fan straight out 3 Confirm the cor...

Страница 295: ...ted Use tweezers or needle nose pliers to lift the fuses straight out of their sockets CAUTION Fuses on the Front Fan module and Rear Fan Adapter boards should not be removed or replaced in a live pow...

Страница 296: ...an To gain access to the rear fan fuses carefully grasp the two tabs on the sides of the shutter assembly Then slide the shutter assembly towards you tilting out the bottom so that the assembly pivots...

Страница 297: ...ial September 2016 Page 297 Figure 144 Rear Fan Fuses Power Consumption Table 129 FANS Power Consumption PX FRONT FAN 15 RU PX FRONT FAN TOP 28 RU PX FRONT FAN BOT 28 RU PX REAR FAN ADPTR PX REAR FAN...

Страница 298: ...rmal conditions for instance if a module is improperly installed or the wrong kind of module is plugged in a slot designed to host another type of module card edge LEDs are used to show diagnostic inf...

Страница 299: ...Works only with specific Back Modules designed for the Platinum system OFF OFF ON Front Module is SD 270Mbps only Works only with specific Back Modules designed for the IP3 system ON OFF ON Front Mod...

Страница 300: ...rks only with specific Back Modules designed for the Platinum system OFF OFF ON Front Module is SD 270Mbps only Works only with specific Back Modules designed for the IP3 system ON OFF ON Front Module...

Страница 301: ...ential September 2016 Page 301 OUTPUT 13 OUTPUT 14 OUTPUT 15 OUTPUT 16 BM Types ON ON OFF ON Back Module contains 2x DensiShield sockets and 4x SFP sockets OFF OFF ON ON Back Module contains 8x BNC co...

Страница 302: ...ule s connector While the Module Interconnect MI is a passive module with no active components on the Module Interconnect there are fuses next to each module s connector These fuses are to prevent dam...

Страница 303: ...Operation Manual Module Interconnect PX BP 28 PX BP 15 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 303 Fuses on the Module Interconnect PX BP 28 Figure 145 Fuses...

Страница 304: ...num IP3 Installation and Operation Manual Module Interconnect PX BP 28 PX BP 15 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 304 Figure 146 Fuses at the top of PX...

Страница 305: ...nd Operation Manual Module Interconnect PX BP 28 PX BP 15 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 305 Figure 147 Fuses on left arm of PX BP 28 Figure 148 Fuse...

Страница 306: ...ary and Confidential September 2016 Page 306 Figure 149 Fuses at the center of the PX BP 28 Fuses on the PX BP 28 Fuse Type Fuse Rating Present on Part Number Slowblow 5 Amps Resource Card Slots 127 1...

Страница 307: ...Operation Manual Module Interconnect PX BP 28 PX BP 15 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 307 Fuses on the Module Interconnect PX BP 15 Figure 150 Fuses...

Страница 308: ...peration Manual Module Interconnect PX BP 28 PX BP 15 2016 Imagine Communications Corp Proprietary and Confidential September 2016 Page 308 Figure 151 Fuses at the top of the PX BP 15 Figure 152 Fuses...

Страница 309: ...ge 309 Figure 153 Fuses at the bottom of the PX BP 15 Module Interconnect Installation The PX BP 28 PX BP 15 Module Interconnect is installed into the IP3 frame at the Imagine Communications manufactu...

Страница 310: ...Suppressor TVS diodes for over current and Transient Voltage protection respectively Besides these components the PX AUX is passive The module connects power and communication signals from the IP3 MI...

Страница 311: ...Imagine Communications Corp Proprietary and Confidential September 2016 Page 311 PX AUX Fuses Figure 155 Fuses on the PX AUX Module Table 135 PX AUX Fuse Ratings Fuse Name Fuse Type Fuse Rating Part N...

Страница 312: ...tary and Confidential September 2016 Page 312 PX AUX Block Diagram 24V_Z1 MI CONECTOR AUX1 ENET1 ENET2 24VA_T 24V_Z2 24VB_T 5V_TOP 5V_T AUX1 ENET1 ENET2 TOP FAN CARD CONNECTOR 24V_Z3 AUX2 ENET3 ENET4...

Страница 313: ...Sync Module Connects the 4 Sync Reference input signals on the PX CBP to both PT SYNC slots Connects the Sync Reference signals from the PT SYNC modules to the MI Backplane PX BP 28 Connects 24V and 5...

Страница 314: ...nel There are four AC DC Rear Panels assembled to the IP3 frame two at the top and two at the bottom The Power Adapter module contains fuses and Transient Voltage Suppressors TVS diodes for over curre...

Страница 315: ...on when not used for connection to PX FR EXPS to avoid accidental shorting that could disturb the IP3 system Figure 158 PX PWR ADPTR Module WARNING This module is not hot pluggable The Frame must be...

Отзывы: