![Imagine Platinum IP3 Скачать руководство пользователя страница 171](http://html1.mh-extra.com/html/imagine/platinum-ip3/platinum-ip3_installation-and-operation-manual_2045405171.webp)
Platinum™ IP3
Installation and Operation Manual
PX-HSRMX-OBG Frame Sync and Mux Output Module
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 171
Optical Output (Fiber Back Modules with SFPs)
Item
Specification
Number of Outputs
16
Package
Dual Channel Transmitter SFP Modules
Connector
LC with PC/UPC polish (single mode fiber)
Wavelengths
1310nm, 1550nm (single mode fiber)
Output Power
-5 dBm min, 0 dBm max (Gennum GF2922)
Supported Video rates
270Mb/s, 1.5Gb/s, 3Gb/s
Supported Formats and Sampling
Structures
ASI, SD SDI, HD SDI, 3G SDI
Bit Error Rate
Complies with SMPTE 297-2006
Electrical Input (Back Module with DensiShield)
Item
Specification
Number of Inputs
8
Connector
FCI DensiShield
Impedance
100 ohms differential
Amplitude
800 mV differenial
Supported Cable Type
FCI 10116746-R0600BULF
Supported Cable Length
6m
Formats
ASI, SD SDI, HD SDI, 3G SDI
Note: Gennum is the supported SFP for all Platinum Framesync Optical Modules.
PX-HSRMX-OBG Operation
Power-Up Sequence
Due to the complexity of the board and its parameter list, it takes about 2 minutes after power-cycling a
board before it is fully operational. About 10 seconds after power-cycling, a board is ready to detect
input signals, but the outputs will not become active until the Resource card has completed uploading
the previously used configuration (parameters).
The readiness of the board is reflected by the read-only
Control Status
parameter. (See General
Parameters (on page 174))
Firmware Upgrade and Backup Image
The modules maintain a backup image of the last working firmware at all times. In the event of an
upgrade failure, the module will revert back to its backup image to maintain operation on the board.