![Imagine Platinum IP3 Скачать руководство пользователя страница 302](http://html1.mh-extra.com/html/imagine/platinum-ip3/platinum-ip3_installation-and-operation-manual_2045405302.webp)
Platinum™ IP3
Installation and Operation Manual
Module Interconnect (PX-BP-28/PX-BP-15)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 302
Module Interconnect (PX-BP-28/PX-BP-15)
The
PX-BP-28
Module Interconnect
(MI)
is the central interconnect module for the 28 RU Platinum IP3
frame and the 15 RU Platinum IP3 frame uses a PX-BP-15.
The Input, Output, Crosspoint, Resource, Alarm and other modules are interconnected by copper traces
in the Backplane. Also, DC power, +24V and +5VL, are distributed within the Backplane to all module's
connector.
While the Module Interconnect (MI) is a passive module with no active components on the Module
Interconnect, there are fuses next to each module's connector. These fuses are to prevent damage to
module connectors and the Backplane. See Fuses on the Module Interconnect (PX-BP-28) (on page 303)
for more details.
PX-BP-28/PX-BP-15 Module Slots
Table 134:
Module Slots on the PX-BP-28/PX-BP-15
Slot Type
PX-BP-28 Slots
PX-BP-15 Slots
Input Module Slots
64
32
Output Module Slots
64
32
Video Crosspoint Module Slots
2
2
Audio TDM Crosspoint Module Slots
2
2
Resource (Control) Module Slots
2
2
Sync Distribution Module Slots
2
2
Output Monitoring Module Slot
1
1
Alarm Expansion Module Slot
1
1
Auxiliary Module Slot
1
1
Power Distribution Slots
2
1