Parameter
Description
R/W
Options
Ext. Reference Lock Error
Reports lock error on external reference
RO
No
Yes
Ext. Reference Validity Error
Reports validity error on external
reference
RO
No
Yes
Ext. Reference Confidence Error
Reports confidence error on external
reference
RO
No
Yes
Ext. Reference Biphase Error
Reports biphase error on external
reference
RO
No
Yes
Ext. Reference Parity Error
Reports parity error on external reference RO
No
Yes
Operating Mode
Sets PM-ADCT-IB/PT-ADCT-IB operating
mode
RW
Auto
Internal
External
0dBFS setting
Sets 0 dBFS setting for analog to digital
conversion
RW
13 dB to 28 dB in 1 dB
increments
Presence Hysteresis (1-16)
Sets the time duration between
acquisition of signal presence and release
of audio muting
RW
7.5 ms to 32.76 s in 500
ns steps
Silence Delay (1-16)
Sets time duration between loss of signal
presence and audio muting
RW
7.5 ms to 32.76 s in 500
ns steps
Silence Disable (1-8)
Disables feature of generating AES silence
when signal is not present (wideband
mode only)
RW
No
Yes
Threshold (1-8)
Sets signal presence threshold (all inputs) RW
0x00 to 0x7F
Sample Frequency Adjust
Adjusts internal mode sampling frequency RW
0x00 to 0xFF
Sampling Frequency Select
Sets the sampling frequency when in
internal mode
RW
32 kHz
44.1 kHz
48 kHz
88.2 kHz
96k Hz
192 kHz
Audio Reference
Selects AES reference input for source
RW
Sync 1
Sync 2
Sync 3
Sync 4
Parameter Hysteresis
Sets hysteresis for parameters needing it
RW
0 to 5 seconds in 500 ns
steps