Platinum™ IP3
Installation and Operation Manual
Audio TDM Crosspoint Module
(PX-ATDM64-X28)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 89
DIP Switches on the PX-ATDM64-X28
DIP switch
SWC2
switch
1
, puts the Freescale Kinetis processor into Failsafe mode. To enable Failsafe,
move
SWC2
switch
1
to the ON position.
After you put the board into Failsafe mode, push the Reset button,
SWC1
, or power cycle the board by
unplugging/plugging the board from the frame. Use the Controller's GUI to upgrade the application.
The following figure shows switch 1,2,3 and 4 in the OFF position. This is the setting that should be used
for normal operation. Make sure the jumpers are restored to this position after performing a failsafe
upgrade. Switch 2, 3 and 4 are reserved for future use.
Figure 31:
DIP Switches on the PX-ATDM64-X28 Module