Required Equipment
Note:
In order to minimize the risk of damage to components, the IP3 frame must be powered down
during PX-FR-EXPS installation. This unit contains Electro Static Discharge Sensitive (ESDS) devices,
recognized handling precautions should be observed.
One Platinum IP3 Frame (PX-FR-28 or PX-FR-15)
Two PX-FR-EXPS (for PX-FR-28) or one PX-FR-EXPS (for PX-FR-15)
One Flash light
Screw Drivers and other hand tools
Power Cables
The PX-FR-28/PX-FR-15 IP3 frames do not need to be specifically configured for the PX-FR-EXPS external
power supplies. 24" or 90" DC power cables must be connected between the IP3 frame and PX-FR-EXPS
frames. AC Power Cords also need to be connected between the IP3 Frame and the External Power
Supply Frame.
24" Male to Male Combination D-Sub (165-100036Q00)
Standard length cable that connects the PX-FR-28/PX-FR-15 Frame to the PX-FR-EXPS.
Note:
Four 24"cables are included when you buy the PX-FR-EXPS frame.
24" cables are recommended to minimize power loss in the system.
If 24" cables are used to connect the PX-FR-EXPS to a PX-FR-28, one PX-FR-EXPS unit must be
installed
above
and one
below
the PX-FR-28.
In case of a PX-FR-15, only a single PX-FR-EXPS unit can be installed, above the frame
90" Male to Male Combination D-Sub (165-100037Q00)
90" cables are a
customer orderable option.
If 90" cables are used to connect the PX-FR-EXPS to a PX-FR-28 frame,
both
PX-FR-EXPS units can be
installed
above
or
below
the PX-FR-28.
In case of a PX-FR-15, the PX-FR-EXPS must be installed on top of the frame
Power Cable Installation Steps (for PX-FR-EXPS to PX-FR-
28/PX-FR-15)
Note: The following steps consider a 28 RU Frame. Follow the same steps for a 15 RU frame, but note
that there can only be one external power supply frame connected, at the top of the 15 RU IP3 Frame.
CAUTION
All AC power lines should be disconnected before attaching the Interface (DC power) cables to
the rear of the frames.