Functional Block Parameter Name
RW
Description
Options
TDM Reference Standard
RO
Indicates the reference standard
detected on the genlock input.
Reference standards marked
with an asterisk can be
detected, but they cannot be
used in connection with the PT-
MADIxx-OBG, since the output
sample rate is always 48kHz.
Unknown
525i 59.94
625i 50
720p 25
720p 29.97
720p 30
720p 50
720p 59.94
720p 60
1080p 23.98
1080p 24
1080p 29.97
1080p 30
1080p 25
1080i 50
1080i 59.94
1080i 60
1080sF 23.98
1080sF 24
DARS 192kHz
DARS 96kHz
DARS 88.2kHz*
DARS 48kHz
DARS 44.1kHz*
DARS 32kHz*
MADI Locking
MADI Reference Source
RW
Selects which physical sync port
the module uses for the TDM
reference
Sync1
Sync2
Sync3
Same as TDM Ref.
MADI Reference Present
RO
Reports the presence of the
reference signal
No
Yes
MADI Reference Locked
RO
Reports the locked status of the
reference signal
No