Platinum™ IP3
Installation and Operation Manual
PX-FRONT-FAN and PX-REAR-FAN Modules
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 295
CAUTION
: The black shutters located behind the fans are necessary to prevent warm air from
recirculating back into the frame. Ensure the shutters are not removed.
Fuses
Front and rear fans on the Platinum IP3 are protected by fuses. If a fan fuse blows, a serious electrical
fault has occurred; the fuse should not be replaced until the electrical fault has been corrected. Use
tweezers or needle-nose pliers to lift the fuses straight out of their sockets.
CAUTION
: Fuses on the Front Fan module and Rear Fan Adapter boards should not be removed or
replaced in a live (powered) Platinum IP3 frame.
Table 128:
Fan Fuses
Location
Fuse Type
Part Number
Front
PSF1
4 A, Slowblow
127-100006Q00
PSF2
4 A, Slowblow
127-100006Q00
FC1
750 mA, Slowblow
127-100004Q00
Rear
PSF1
5 A, Slowblow
127-100010Q00
PSF2
5 A, Slowblow
127-100010Q00
PSF3
750 mA, Slowblow
127-100004Q00
Fuses on Front Fan Modules
Front Fan fuses are visible inside the Front Fan module array. To inspect or remove fuses, first remove
the array. Then remove the fuses by lifting them straight out of their sockets.
Figure 142:
Front Fan Fuses (Top Module Shown)