IHP.us.com
900861-00D
32
Main Burner Orifice
(OAS-LP#)
Low Rate Set Screw
(ECO-LSS-#)
Figure 44 - Kit Contents
Gas conversion kits are available to adapt your appliance from the
use of one type of gas to the use of another. These kits contain all
the necessary components needed to complete the task including
labeling that must be affixed to ensure safe operation.
Kit part numbers are listed here and the following steps detail the
conversion procedure. Refer to the instructions provided with the
conversion kit when performing any gas conversion.
TOOLS / SUPPLIES NEEDED
Flat bladed screwdriver
Needle nose pliers
Pipe joint compound or teflon tape
Gas leak test solution
KIT CONTENTS
(1) OAS-LP# (brass orifice) and
(1) ECO-LSS# (brass low rate set screw),
(1) LP Conversion Label (placed next to blank space on rating
label),
(1) Installation Instruction Sheet
CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DIS-
CONNECTING THE ELECTRICAL POWER, BEFORE PROCEEDING
WITH THE CONVERSION.
ATTENTION: AVANT D’EFFECTUER LA CONVERSION,
COUPEZ D’ABORD L’ALIMENTATION EN GAZ, ENSUITE, COUPEZ
L’ALIMENTATION ÉLECTRIQUE.
READ ALL THE STEPS BEFORE STARTING THE CONVERSION. IN-
STALLER NOTICE: THESE INSTRUCTIONS MUST BE LEFT WITH THE
APPLIANCE.
When installing gas components use pipe joint compound or Teflon
tape on all pipe fittings before installing (Do not use pipe joint
compounds on flare fittings).
THE APPLIANCE MUST BE OFF AND COLD BEFORE PERFORMING
THE GAS CONVERSION.
ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS IN THE INSTAL-
LATION AND OPERATION MANUAL PROVIDED WITH THE APPLIANCE
APPLY TO THESE INSTRUCTIONS.
In Canada:
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH
THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS
OF THE CAN/CGA-B149.1 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX
RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT
JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE
D’INSTALLATION CAN/CGA-B149.1.
WARNING
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer’s instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instruction
is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency
is responsible for the proper installation of this kit. The
installation is not proper and complete until the opera-
tion of the converted appliance is checked as specified
in the manufacturer’s instructions supplied with the kit.
The qualified service agency performing this installation
assumes responsibility for this conversion.
AVERTISSEMENT
Cette trousse de conversion doit être installée par un
technicien agréé, selon les instructions du fabricant et
selon toutes les exigences et tous les codes pertinents
de l’autorité compétente. Assurez-vous de bien suivre les
instructions dans cette notice pour réduire au minimum
le risque d’incendie, d’explosion ou la production de
monoxyde de carbone pouvant causer des dommages
matériels, des blessures ou la mort. Le tecnicien agréé
est responsable de l’installation de cette trousse.
L’installation n’est pas adéquate ni complète tant que
le bon fonctionnement de l’appareil converti n’a pas été
vérifié selon les instructions du fabricant fournies avec
la trousse. Le fournisseur de service qualifié ayant
réalisé l'installation assume les responsabilités liées à
la conversion.
NATURAL GAS TO PROPANE GAS CONVERSION