IHP.us.com
900861-00D
2
Safety ............................................................................................ 2-3
Local Codes ......................................................................................3
Installation Precautions
............................................. 4-6
Gas Line and Cross Ventilation Requirements .................5
Hard piping and High Elevation ...................................6
Fireplace Specifications ...................................................................7
Single-Sided Fireplace Application
................................8-10
Dimensions; Combustible Clearances; Mantel Clearances ...9
Framing with Metal Studs ........................................ 10
See-Through Fireplace Application
............................. 11-14
Converting Fireplace to a See-Through Model ................ 12
Dimensions; Combustible Clearances; Mantel Clearances . 13
Framing with Metal Studs ........................................ 14
LED Lighting Installation .......................................................... 15-22
Wiring Diagrams ....................................................................... 20-22
Final Preparation
.................................................. 23-27
Installation of Media in Burner Pan/Trough & Pilot Test ...... 24
Installation of Hoods .............................................. 25
Installation of Windshield ........................................ 26
Flame Height ....................................................... 27
Operation
............................................................... 28
Lighting Instructions .............................................. 28
Product Reference Information .................................. 28
Fireplace Maintenance ...................................................................29
Troubleshooting ........................................................................ 30-31
Optional Accessories .....................................................................31
Gas Conversion Instructions .................................................... 32-35
Replacement Parts ................................................................... 36-38
Warranty
............................................................... 39
This fireplace ships from the factory as a single-sided
fireplace with the option of removing the back panels to
convert it into a see-through fireplace. Your specific ap-
plication, single-sided or see-through will determine how
you install and frame this fireplace. Carefully read through
this manual to understand.
DESCRIPTION:
These Outdoor fireplace models come ready to op-
erate with HI/LO capabilities once installation is complete. They
use an electronic ignition that runs off a 7.5VDC adaptor. In ad-
dition, each fireplace is equipped with LED lighting as a standard
feature. Each model can operate the LED lights with or without
the fireplace operating. The LED lights run off of a 12-volt DCV
adaptor.
These are radiant fireplaces only and do not have a fan option.
Do not burn real wood or other combustible materials in these fire-
TABLE OF CONTENTS
SAFETY
places.
Use only approved media. All models are shipped as-
Natural Gas but can be converted to Propane Gas by ordering the
Natural Gas but can be converted to Propane Gas by ordering the
optional conversion kit
optional conversion kit
(see Page 32).
(see Page 32).
There is no top or rear
There is no top or rear
venting required for this fireplace, however, it is mandatory to
venting required for this fireplace, however, it is mandatory to
provide adequate clearances according to this manual and cross
provide adequate clearances according to this manual and cross
ventilation in the enclosure. The burner assembly is removable
ventilation in the enclosure. The burner assembly is removable
for service. NEVER obstruct the front opening(s) of the fireplace.
for service. NEVER obstruct the front opening(s) of the fireplace.
ALWAYS USE CAUTION WHEN USING THE FIREPLACE
Extra caution should be taken when lighting a fireplace when
heavy rains, high humidity and moisture are present. Light the
fireplace and leave the area while the heat dissipates any mois-
ture out of the media. We strongly recommend that during this
drying out time that you monitor the fireplace from a distance.
This drying out period should be no less than 30 minutes. Con-
tinue monitoring the flame from a safe distance to ensure that all
popping has ceased before fully enjoying the fire.
1. This appliance is configured from the factory only as Natural
gas. This appliance can be converted to LP gas.
2. Do not place Propane (LP) supply tanks inside any structure.
Locate propane tanks outdoors.
3. This fireplace is to be used only outdoors in a well ventilated
space and shall not be used in a building, garage, or any other
enclosed area.
4. Do not use this fireplace as a wood burning fireplace. Use only
high temperature media approved for use with this fireplace.
5. Do not use this fireplace to cook or burn paper or other objects.
6. Do not use if exposed to or under water. Immediately call a
qualified service technician to inspect the fireplace and re-
place any part of the control system and any gas control which
has been under water.
7. Turn fireplace OFF and let cool before servicing. Only a quali-
fied service person should perform service.
8. To prevent performance problems in Propane (LP) fireplaces,
do not use a Propane tank less than 100lbs. capacity.
IT IS IMPORTANT TO READ THROUGH THE ENTIRE
INSTALLATION MANUAL BEFORE BEGINNING INSTALLA-
TION OF THIS FIREPLACE!!
HOT GLASS
WILL
CAUSE BURNS
DO NOT TOUCH
GLASS UNTIL COOLED
NEVER
ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appli-
ance and shall be installed for the
protection of children and other at-risk
individuals.
DANGER