background image

Barcelona Lights | VRE4600 |ODLVF

P900861-00

 

-  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

 

-  

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use any 

phone in your building. 

•  Leave the building immediately.

• Immediately call your gas supplier from a neighbor’s 

phone.  Follow the gas supplier’s instructions. 

•  If  you  cannot  reach  your  gas  supplier,  call  the  fire 

department.

 -   Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could 

result in serious injury, death, or property damage.

        AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION

Le non-respect Des avertissements de sécurité pourrait d’entraîner 

des blessures graves, la mort ou des dommages matériels.

 -  Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs 

ou liquides inflammables dans le voisinage de cet appareil 

ou de tout autre appareil.

 -  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir des 

téléphones se trouvant dans le bâtiment où vous trouvez. 

•  Sortez immédiatement de bâtiment.

• Appelez immédiatement votre fournisseur de gaz depuis 

un voisin. Suivez les instructions du fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez 

le service des incindies.

 -   L’installation et l’entretien doivent être assurés par un instal-

lateur ou un service d’entretien qualifié ou par le fournisseur 

de gaz.

WHEN USED AS AN OUTDOOR APPLIANCE

CARBON MONOXIDE WARNING

•  This appliance can produce 

carbon monoxide which has 

no odor.

•  Using it in an enclosed space 

can kill you.

•  Never use this appliance in 

an enclosed space such as a 

camper, tent, car or home.

 

WARNING: For Outdoor Use Only.

 

DANGER

IF YOU SMELL GAS:

1.  Shut off gas to appliance.

2.  Extinguish any open flame.

3.  If odor continues, keep away from the appli-

ance and immediately call your gas supplier 

or fire department. 

 

WARNING: Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 

An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read 

the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.

Installation and Operation Instructions

P/N 900861-00    REV. D   03/2020

Report No. #20-024

Ce manuel est disponible en francais, 

simplement en faire la demande. Nu-

méro de la pièce 900861-01.

OUTDOOR DECORATIVE GAS FIREPLACE

Models

INSTALLATION PRECAUTION: This fireplace requires a minimum 

18-square inches (per side) of cross ventilation. Failure to provide 

proper ventilation can void the warranty.

ODLVF36ZEN, ODLVF48ZEN, ODLVF60ZEN, ODLVF72ZEN

Содержание ODLVF36ZEN

Страница 1: ...entretiendoiventêtreassurésparuninstal lateurouunserviced entretienqualifiéouparlefournisseur de gaz WHEN USED AS AN OUTDOOR APPLIANCE CARBON MONOXIDE WARNING This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING For Outdoor Use Only DANGER IF YOU SMELL GAS 1 Sh...

Страница 2: ... required for this fireplace however it is mandatory to provide adequate clearances according to this manual and cross provide adequate clearances according to this manual and cross ventilation in the enclosure The burner assembly is removable ventilation in the enclosure The burner assembly is removable for service NEVER obstruct the front opening s of the fireplace for service NEVER obstruct the...

Страница 3: ...SI Z223 1 NFPA 54 USA latest edition or CAN CGA B149 1 Natural gas and propane installation code Canada latest edition AN OUTDOOR SPACE IS DEFINED AS FOLLOWS PER ANSI Z21 97 Outdoor spaces An appliance is considered to be outdoors if in stalled with shelter no more inclusive than SAFETY continued LOCAL CODES a With walls on all sides but with no over head cover b Within a partial enclosure which i...

Страница 4: ...end of the fireplace See Figure 3 Page 5 10 Never fill the cavity under and around the valve box with any material this is air space necessary for ventilation 11 Only non combustible materials i e metal studs and ce ment board should come in direct contact with any part of the fireplace Underneath area should be non combustible or a flat level combustible surface according to the clearances specif...

Страница 5: ...s line must have a predetermined location to en able it to be installed Figure 1 shows one example of an inlet gas line with a gas shut off at the fireplace This allows a techni cian to shut the inlet gas supply OFF and remove the burner for servicing It is imperative that the flex line from the gas shut off be long enough to lift out burner pan for service Ensure you follow the local and state ga...

Страница 6: ...ed above 100 000 BTU 1 Turn OFF gas supply system NOTE All gas connections except for brass to brass require the following Clean pipe threads using either a wire brush or steel wool Apply pipe sealant to the fittings before making any connection BE CARE FUL Ensure all gas connections are snug but do not over tighten 2 Extend the gas supply using minimum of 3 4 black iron pipe or an approved flexib...

Страница 7: ...uring operation Figure 4 Remove Fireplace from Skid SPECIFICATIONS Inlet Gas Pressure Natural Gas NG Propane LP Minimum Inlet 5 0 WC 1 24 kPa 10 5 WC 2 61 kPa Maximum Inlet 10 5 WC 2 61 kPa 13 0 WC 3 23 kPa Normal Inlet 7 0 WC 1 74 kPa 11 0 WC 2 74 kPa Manifold Gas Pressure Natural Gas NG Propane LP Normal Mani fold 4 WC 1 00 kPa 10 0 WC 2 49 kPa Table 2 Gas Pressures Model NG Factory Orifice NG B...

Страница 8: ...er wire harness 1 Manual shut off gas valve 1 Pilot Hood 1 OFP Pilot Screen 1 Dielectric Grease for electronic connections Windshield Parts Box Contents 4 Glass Windshields inside firebox 8 Glass Windshield Supports 4 for singled sided 8 for see through fireplace 2 Stainless Steel Hoods 1 for singled sided 2 for see through fireplace 14 Stainless Machine Screws For hood install depending on size a...

Страница 9: ... 407mm 16 1 4 413mm 11 1 2 292mm 8 3 4 222mm 6 153mm 46 1 2 1181mm ODLVF72ZEN 76 1931mm 72 1829mm 33 1 2 850mm 16 407mm 16 1 4 413mm 11 1 2 292mm 8 3 4 222mm 6 153mm 46 1 2 1181mm Table 3 Fireplace dimensions and clearances Ensure you follow the proper clearances during installation Figure 6 Single sided fireplace clearance to combustibles See Table 3 Figure 7 Open front fireplace mantel clearance...

Страница 10: ...able 4 Fireplace framing dimensions Figure 8 Framing dimensions using all non combustible materials for single sided fireplace refer to Table 4 NOTE This outdoor fireplace is not a load bearing fireplace All finishing materials must be supported by the sur rounding structure and not rely on the fireplace itself SINGLE SIDED FRAMING DIMENSIONS WITH METAL STUDS Metal Studs Metal Studs A B Metal stud...

Страница 11: ... Stainless Steel Vents used to ventilate enclosure 12 Black Screws Nuts Washers for 6x12 vents 1 Installation manual for vent kit 1 24 inch LED wire harness 1 10 foot valve system module wire harness 1 LED 10 foot controller wire harness 1 Manual shut off gas valve 1 Pilot Hood 1 OFP Pilot Screen 1 Dielectric Grease for electronic connections Windshield Parts Box Contents 4 Glass Windshields insid...

Страница 12: ... and bottom screws on the rear panel The naling flange will remain in place The back panel will remove as one panel The number of screws removed will vary with each fireplace model NOTE Nailing fin will be loose when removing the top screws Secure the nailing fin back into place after back panel is removed Step 2 The back panel will not be used again in the see through application Discard back pan...

Страница 13: ...1 2 1180mm BarcelonaLights72ZEN or VRE4672ZEN 76 1931mm 72 1829mm 33 1 2 850mm 16 407mm 16 407mm 11 1 2 292mm 8 3 4 222mm 36 915mm 46 1 2 1180mm Table 5 Fireplace dimensions and clearances Figure 11 See through fireplace clearance to combustibles See Table 5 This fireplace ships from the factory as a single sided fireplace but by removing the back panels you can convert it into a see through fire ...

Страница 14: ...Fireplace framing dimensions Figure 13 Framing dimensions using all non combustible materials for see through fireplace refer to Table 6 NOTE This outdoor fireplace is not a load bearing fireplace All finishing materials must be supported by the sur rounding structure and not rely on the fireplace itself SEE THROUGH FRAMING DIMENSIONS WITH METAL STUDS Metal Studs A B Metal studs shown in gray Bott...

Страница 15: ...opposite side of inlet will create more room for LED installation Figure 16 shows GFCI gang box in stalled Step 2 Find mounting location for the GFCI gang box Figure 15 shows flat area underneath burner pan Mount box underneath the burner pan below the square cutout hole area Figure 16 shows the GFCI outlet double gang junction box with a weatherproof cover mounted underneath the fireplace Burner ...

Страница 16: ... left and 1 clip on the right side of the inner fireplace side panel Note If you are preparing a see through fireplace you will install a total of 8 glass clips two for each open side The additional clips are supplied with the see through conversion kit Note If you are preparing a see through fireplace you will install a total of 8 glass clips 4 on each open side Figure 18 Shows clip installed on ...

Страница 17: ...direction to ensure wires will connect Figure 21 Installing LED lights and channel Figure 22 LED installed in retainer clip inside fireplace Step 5 Remove the LED right channel assembly from the carton The front of the channel has a shield facing the front with the LED wire hanging on the right side See Figure 20 and Figure 21 for details NOTE If you are installing into a see through fireplace you...

Страница 18: ...ap of the female connector securely over the male connector Note If you are using one set of LED lights the other female connec tor Cat No F3499 will not be used See Figure 24 Step 9 Attach Cat No F3499 to F3500 using the molex con nectors After connecting the LED lights into the F3500 wire harness insert the 12 volt adapter 77102 with terminals into the red black wires of LED wireharness Plug the...

Страница 19: ...e RGB control box into the desired location CAUTION AVOID USING EXCESSIVE FORCE WHEN INSTALLING ANY CONNECTORS Step 13 Remove the 8 PIN module wire harness Cat No F3500 from the components part box Locate the 8 PIN male connector from the valve box under the fireplace and connect it to the 8 PIN female end of the wire harness Connectors only attach one way press together until it snap locks into p...

Страница 20: ...1 00D Switch Cover LED ON OFF ON OFF HI LOW LEARN IPI CONT PILOT RGB DIMMER PN 77116 PN 77115 PN AF 4000ADP24 PN AF4000ADP48EXT PN 77102 PN 77113 Figure 27 Overview of fireplace wiring LED LIGHTING INSTALLATION Continued ...

Страница 21: ...ls Inside valve box REPRESENTS COMPONENTS INSIDE LED CONTROLLER BOX 12VDC adaptor inside a weatherproof box REPRESENTS COMPONENTS INSIDE FIREPLACE Cat No F3482 7 5VCD adaptor powers gas valve system Brown Blue Yellow Black Red BR BL B Y BR BL B Y BL B R G R B R B BL G BL G B B R R BL G B B R R BR BL B Y R ID 77113 order RGB control box F3483 if needed ID 77114 order RGB control box F3483 if needed...

Страница 22: ...ILOT TUBE S I SWITCHES POWER MOTOR COMM BATT V BRONZE INSULATED WIRE BLACK WIRE BRASS WIRE GROUND MOTOR DRIVE WIRES TO 120VAC POWER SWITCHES MOUNTED IN RGB CONTROL ASSEMBLEY LOW RATE SET SCREW These Fireplaces are equipped with an electronic gas valve and has an IPI CPI electronic ignition system The IPI CPI switch allows the pilot to be switched from intermittent mode to continuous mode IPI Inter...

Страница 23: ...s shown in Figure 31 The ignition screen sit on top of the burner tube Fig 31 Installing ignition screen Step 22 Place pilot hood on top of the pilot box and ensure if sits flat providing ventilation for the pilot at the front edge of the burner pan See Figures 32 and 33 Figure 32 Pilot hood installing over top of pilot box NOTE The pilot hood will have a plastic film that must be re moved before ...

Страница 24: ... Figures 34 36 Place media fireglass into the trough area first as shown in Figure 35 Use the remaining media to fill the burner pan equally on both sides Install only one layer over top of the ignition screen Figure 32 just enough to camo flauge it Keep media in burner pan the same level as the trough to allow the burner area to appear as one complete burner pan IMPORTANT Media can only be placed...

Страница 25: ...secure the hood to the fireplace except the 72 inch model which uses seven 7 screws 77129 8 32x1 2 stainless pan head to secure the hood The hood protrudes 1 inch from fire place opening Figure 38 shows hole location and installation process for hood installation The protruding area of the hood is to be angled downward for proper installation see Hood Detail below Hood Screw Locations FRONT VIEW S...

Страница 26: ...ip supporting the glass at the top and bottom as you handle it See Figure 40 As the glass enters the clip the bottom edge of the glass will rest in place on the bottom of the clip Install the second glass pane in the same manner as de scribed in Figure 40 Both glass panels should be level when installed Center glass between clips after installation Step 1 Step 2 Front of Fireplace LED HOT GLASS WI...

Страница 27: ...transmitter within 60 seconds The code is accepted when you hear 4 short beeps in rapid succession Security codes will be retained in memory indefinitely if power is removed Note Control module accepts a total of three 3 wireless transmitters 2 To Clear Codes Press and hold learn switch on for 6 seconds to clear all transmitter security codes retained in memory Codes are clear when you hear three ...

Страница 28: ...ance indoors is permissible only if it has been disconnected from its fuel supply Natu ral or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance 3 These appliances are not designed or intended to be used for cooking Do not barbecue heat food or roast marsh mallows in this appliance Doing so could damage...

Страница 29: ...eans the metal ef fectively 3 Run a nylon scrub brush against any stubborn soot to re move it from the metal Avoid using a metal scrub brush since this can result in scratching 4 Buff the metal with a damp rag to remove any remaining soap or vinegar and then dry it with a dry rag 6 Over time stainless steel parts can discolor when heated usually a golden or brown hue This discoloration is normal a...

Страница 30: ...l media and unplug weep holes Clean or install new media free of dust and dirt 2 Ensure fireplace has proper drainage for water and proper ventilation to dry out Whistling Noises 1 Check media to ensure it is not too tightly packed around the burner tube 2 Ensure a non whistling flex connector is being used Fireplace Won t Stay Lit 1 Check alignment of pilot flame through ignition hole on Page 25 ...

Страница 31: ...ck Onyx Glass Media 5lb F3508 GLO CRYSTAL Diamond Crystal Glass Media 5lb F3509 GLO LT BLUE Sapphire Blue Glass Media 5lb Remote Control Kit Cat No Model Description F2687 EF BRCK Remote Control Manual ON OFF opera tion Off Continuous pilot feature Ecoflow Control Kits Cat No Model Description F2660 EF WWRCK Wireless Wall Switch On Off High Low ON OFF HI LOW Continuous Pilot ON OFF beeping Cause P...

Страница 32: ... THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN CGA B149 1 INSTALLATION CODE LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D INSTALLATION CAN CGA B149 1 WARNING Thisconversionkitshallbeinstalledbyaqualifiedservice agencyinaccordancewiththemanuf...

Страница 33: ... it with an arrow Look carefully on the stem it may be difficult to read The gas type is determined with the arrow pointing at the alumi num cap as seen in Figures 47 and 48 Step 5 On the underneath side of the aluminum cap is a plastic stem Using a 6mm wrench remove the stem unscrew the stem counter clockwise turn it over and install the opposite end back into the cap See Figure 47 NATURAL GAS TO...

Страница 34: ...rn clockwise until it stops approximately 2 full revolutions See Figure 51 Once the orifice has been converted to LP then re install the pi lot hood ensure the clip is in place if removed and mount the metal pilot box back into place ins the same manner you removed it from the burner pan See Figure 52 as a reference NOTE Figures 50 and 52 provide a visual reference of the pilot ori fice from Natur...

Страница 35: ... the blank area on the rating plate Step 16 Conversion is now complete NATURAL GAS TO PROPANE GAS CONVERSION Continued Low Rate Set Screw PressureTap PressureTap Figure 53 Detailed location of low rate set screw Step 11 Remove the low rate set screw with a flat bladed screw driver turning the screw counter clockwise The set screw has a rubber O ring on the outer portion of the screw as a result th...

Страница 36: ...ss Windshield 1 2 Drawings Not to Scale 5 11 18 Not all replacement parts are depicted in the drawings above but all are listed on Pages 37 and 38 9 S I SWITCHES POWER MOTOR COMM BATT V 15 16 14 17 1 2 PSI SPAIN 7 4 3 6 Pkg of 4 8 10 19 20 21 22 23 ...

Страница 37: ...15 7 EcoFlow Gas Valve with Step Motor with ECO LSS 34 for 48 Model F3516 7 EcoFlow Gas Valve with Step Motor with ECO LSS 27 for 60 Model F3517 7 EcoFlow Gas Valve with Step Motor with ECO LSS 44 for 72 Model F3471 8 Natural Gas Regulator REG C80K NG convertible to LP See Page 33 F3510 9 Side Mount Pilot Assembly complete assembly with TC ECO VK Pilot J7935 10 Ignition Control Module includes 8 p...

Страница 38: ...age 26 F3488 30 60 Fireplace Hood not depicted see Figure 37 Page 26 F3489 31 72 Fireplace Hood not depicted see Figure 37 Page 26 F3490 32 Cross Ventilation Kit VENT KIT 6x12 not depicted F3535 33 Remote Wire Harness AF4000ADP48EXT not depicted F2690 NOTE All items are shipped as one replacement part unless noted in the description WARNING Never use substitute materials Use of non approved parts ...

Страница 39: ...ane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application...

Страница 40: ... Ce produit est conçu pour brûler soit du gaz naturel ou du gaz propane seulement Brûler des combustibles conventionnels tels que du bois charbon ou tout autre combustible solide peut occasionner des dommages au produit produire des températures élevées et peut causer un risque d incendie c dommages causés par manque d entretien selon les instructions fournies avec le produit d dommages réparation...

Страница 41: ...___________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________...

Страница 42: ... local distributor for fireplace code information Printed in U S A 2017 Innovative Hearth Products P N 900861 00 Rev D 03 2020 1769 East Lawrence Street Russellville AL 35654 P900861 00 IHP us com Record the following important information about your fireplace Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name ...

Отзывы: