IDT Transparent Mode Operation
Generic PCI to PCI Bridge Register Definition
PES12N3 User Manual
9 - 48
June 7, 2006
Notes
IOEXPINTF - I/O Expander Interface (0x0B8)
‘
24
BUSY
RO
0x0
EEPROM Busy. This bit is set when a serial EEPROM
read or write operation is in progress.
0x0 - (idle) serial EEPROM interface idle
0x1 - (busy) serial EEPROM interface operation in
progress
25
DONE
RW1C
0x0
EEPROM Operation Completed. This bit is set when a
serial EEPROM operation has completed.
0x0 -
(notdone) interface is idle or operation in progress
0x1 -
(done) operation completed
26
OP
RW
0x0
EEPROM Operation Select. This field selects the type of
EEPROM operation to be performed when the DATA field
is written
0x0 - (write) serial EEPROM write
0x1 - (read) serial EEPROM read
31:27
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
7:0
PBHPS
RW
0x0
Port B Hot-Plug Signals. Each bit in this field corresponds
to a port B hot-plug signal. Reading this field returns the
current value of the corresponding hot-plug signals (i.e.,
the input values last read from the I/O expander and output
values supplied to the I/O expander).
Writes to this field are ignored unless the I/O Expander
Test Mode (IOEXTM) bit is set. When the IOEXTM bit is
set, the value for outputs supplied to the I/O expander cor-
responds to the value written to this field instead of the
value supplied by internal logic. Bits in this field which cor-
respond to inputs are always read-only, even when the
IOEXTM bit is set.
15:8
PCHPS
RW
0x0
Port C Hot-Plug Signals. Each bit in this field corresponds
to a port C hot-plug signal. Reading this field returns the
current value of the corresponding hot-plug signals (i.e.,
the input values last read from the I/O expander and output
values supplied to the I/O expander).
Writes to this field are ignored unless the I/O Expander
Test Mode (IOEXTM) bit is set. When the IOEXTM bit is
set, the value for outputs supplied to the I/O expander cor-
respond to the value written to this field instead of the value
supplied by internal logic. Bits in this field which correspond
to inputs are always read-only, even when the IOEXTM bit
is set.
23:16
Reserved
RO
0x0
Reserved field.
24
RELOADIOEX
RW
0x0
Reload I/O Expander Signals. Writing a one to this field
results in an I/O expander SMBus transaction that
refreshes all I/O expander input and output signal values.
This bit always returns a zero when read.
Bit
Field
Field
Name
Type
Default
Value
Description
Содержание 89HPES12N3
Страница 10: ...IDT Table of Contents PES12N3 User Manual iv June 7 2006 Notes...
Страница 14: ...IDT List of Figures PES12N3 User Manual viii June 7 2006 Notes...
Страница 36: ...IDT Clocking Reset and Initialization Reset PES12N3 User Manual 2 8 June 7 2006 Notes...
Страница 40: ...IDT Link Operation Slot Power Limit Support PES12N3 User Manual 3 4 June 7 2006 Notes...
Страница 50: ...IDT Switch Operation Switch Core Errors PES12N3 User Manual 4 10 June 7 2006 Notes...
Страница 54: ...IDT Power Management Active State Power Management PES12N3 User Manual 5 4 June 7 2006 Notes...
Страница 62: ...IDT Hot Plug and Hot Swap Hot Swap PES12N3 User Manual 6 8 June 7 2006 Notes...
Страница 78: ...IDT SMBus Interfaces Slave SMBus Interface PES12N3 User Manual 7 16 June 7 2006 Notes...
Страница 142: ...IDT Transparent Mode Operation Generic PCI to PCI Bridge Register Definition PES12N3 User Manual 9 62 June 7 2006 Notes...
Страница 148: ...IDT Test and Debug SerDes Test Clock PES12N3 User Manual 10 6 June 7 2006...
Страница 158: ...IDT JTAG Boundary Scan Usage Considerations PES12N3 User Manual 11 10 June 7 2006 Notes...