WATER LEVEL CHECK
The float valve is factory-set for the proper water level.
If adjustments are necessary:
1. Verify the ice machine is level.
2. Place the main 'ICE/OFF/WASH' switch to the 'ON'
position, and wait until the float valve stops adding
water.
3. Adjust the water level to 1/4” to 3/8” (6.3 to 9.5 mm)
below the standpipe:
A. Loosen the two screws on the float valve bracket.
B. Raise or lower the float valve assembly as
necessary, then tighten the screws.
C. Move the main 'ICE/OFF/WASH' toggle switch to
the 'OFF' position. The water level in the trough
will rise above the standpipe and run down the
drain.