Ice Machine Cycles Into Harvest Before Water Contact
with the Ice Thickness Probe
Step 1
Move the 'ICE/OFF/WASH' switch to 'OFF' and
back to 'ON' to start a new cycle. Wait until the water
starts to flow over the evaporator.
Step 2
Disconnect the ice thickness probe from the
control box terminal.
Step 2 Disconnect probe from control board terminal.
Monitoring Harvest Light
Correction
The ice machine remains in
the freeze sequence.
The ice thickness probe is
causing the malfunction. Verify
that the Ice Thickness probe is
adjusted correctly.
The ice machine cycles from
freeze to harvest.
The control board is causing the
malfunction.
1
09
Содержание IC-0170A
Страница 1: ...Undercounter Ice Machines Technician s Handbook Revision Date 1 24 22...
Страница 2: ......
Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 17: ...16 How to Read a Serial Number Full Serial Number...
Страница 154: ...WU 0100 WIRING DIAGRAM Self Contained Air cooled 153...
Страница 155: ...IC 0170 IU 0170 IC 0220 IU 0220 WIRING DIAGRAM Self Contained Air cooled 154...
Страница 156: ...Printed Circuit Bards PCB WU 0100 PCB 155...
Страница 161: ...SPACE FOR TECHNICIAN S NOTES...
Страница 162: ...SPACE FOR TECHNICIAN S NOTES...
Страница 163: ...SPACE FOR TECHNICIAN S NOTES...
Страница 164: ...SPACE FOR TECHNICIAN S NOTES...
Страница 165: ......