5.
Water Pump
Once both float switches are satisfied, the water pump
energizes and water flows over the evaporator.
Slush Thermistor
When the temperature of the water reaches 34°F the water
pump de-energizes for approximately 15 seconds.
When the water pump energizes again, the water inlet valve
also energizes to fill the water trough with fresh water for
approximately 5 seconds.
Dual
Float
s
(
Prior to TB Serial Numbers
)
The freeze cycle
continues until the water drops below the high-level/ice
thickness float switch & low-level harvest float switch,
closing them both for approximately 7 seconds, which
initiates the harvest cycle.
Ice Thickness Probe (
On or After TB Serial Numbers
)
The freeze cycle continues until water touches the ice
thickness sensor for 7 continuous seconds, which initiates
the harvest cycle.
56
Содержание IC-0170A
Страница 1: ...Undercounter Ice Machines Technician s Handbook Revision Date 1 24 22...
Страница 2: ......
Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 17: ...16 How to Read a Serial Number Full Serial Number...
Страница 154: ...WU 0100 WIRING DIAGRAM Self Contained Air cooled 153...
Страница 155: ...IC 0170 IU 0170 IC 0220 IU 0220 WIRING DIAGRAM Self Contained Air cooled 154...
Страница 156: ...Printed Circuit Bards PCB WU 0100 PCB 155...
Страница 161: ...SPACE FOR TECHNICIAN S NOTES...
Страница 162: ...SPACE FOR TECHNICIAN S NOTES...
Страница 163: ...SPACE FOR TECHNICIAN S NOTES...
Страница 164: ...SPACE FOR TECHNICIAN S NOTES...
Страница 165: ......