DIAGNOSING ICE THICKNESS CONTROL CIRCUITRY
Ice Machine Does Not Cycle Into Harvest when Water
Contacts the Ice Thickness Control Probe
Step 1
Move the 'ICE/OFF/WASH' switch to 'OFF' and
back to 'ON' to start a new cycle. Wait until the water
starts to flow over the evaporator.
Step 2
Use a jumper wire between the (red) ice
thickness probe connector on the outside of the control
box and any cabinet ground.
Step 2 Jumper red control box
terminal to ground
Monitoring Harvest Light
Correction
The ice machine cycles from
freeze to harvest.
The ice thickness probe is
causing the malfunction.
The machine does not
cycle into harvest.
The control board is causing the
malfunction.