WU-0100 Refrigeration Diagnostics
This machine uses a capillary tube metering device
system. An irregular ice fill pattern could indicate an
improper refrigerant charge.
If this is determined to be the case, recover any
refrigerant left in the system, evacuate the system and
weigh in a new charge according the the machine's data
plate.
NOTE: If the machine is low on charge, find the source
of the leak before charging the system.