If
you
have
just
added
new
software
or
a
new
option
and
your
server
is
not
working,
do
the
following
before
using
the
error
symptom
charts:
v
Remove
the
software
or
device
that
you
just
added.
v
Run
the
diagnostic
tests
to
determine
if
your
server
is
running
correctly.
v
Reinstall
the
new
software
or
new
device.
In
the
following
table,
if
the
entry
in
the
FRU/action
column
is
a
suggested
action,
perform
that
action;
if
it
is
the
name
of
a
component,
reseat
the
component
and
replace
it
if
necessary.
The
most
likely
cause
of
the
symptom
is
listed
first.
Note:
See
“System”
on
page
160
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
CD-ROM
drive
problems
Symptom
FRU/action
CD-ROM
drive
is
not
recognized.
1.
Verify
that:
v
The
IDE
channel
to
which
the
CD-ROM
drive
is
attached
(primary
or
secondary)
is
enabled
in
the
Configuration/Setup
Utility
program.
Note:
On
a
server
with
a
single
IDE
channel,
only
the
primary
channel
can
be
used.
v
All
cables
and
jumpers
are
installed
correctly.
v
The
correct
device
driver
is
installed
for
the
CD-ROM
drive.
2.
Run
CD-ROM
drive
diagnostics.
3.
Cable.
4.
CD-ROM
drive.
5.
System
board.
Note:
See
“System”
on
page
160
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Diskette
drive
problems
Symptom
FRU/action
Diskette
drive
activity
LED
stays
on,
or
the
system
bypasses
the
diskette
drive.
1.
If
there
is
a
diskette
in
the
drive,
verify
that:
v
The
diskette
drive
is
enabled
in
the
Configuration/Setup
utility
program.
v
The
diskette
is
good
and
not
damaged.
(Try
another
diskette
if
you
have
one.)
v
The
diskette
is
inserted
correctly
in
the
drive.
v
The
diskette
contains
the
necessary
files
to
start
the
server.
v
The
software
program
is
working
properly.
v
The
cable
is
installed
correctly
(in
the
proper
orientation).
2.
Run
diskette
drive
diagnostics.
3.
Cable.
4.
Diskette
drive.
5.
System
board.
Chapter
6.
Symptom-to-FRU
index
139
Содержание XSERIES 255 TYPE 8685
Страница 1: ...xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 2: ......
Страница 3: ...xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 6: ...iv xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 20: ...10 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 126: ...116 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 189: ...Appendix B Related service information 179...
Страница 190: ...180 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 191: ...Appendix B Related service information 181...
Страница 192: ...182 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 193: ...Appendix B Related service information 183...
Страница 194: ...184 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 195: ...Appendix B Related service information 185...
Страница 196: ...186 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 209: ...Appendix B Related service information 199...
Страница 210: ...200 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 211: ...Appendix B Related service information 201...
Страница 212: ...202 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 213: ...Appendix B Related service information 203...
Страница 214: ...204 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 224: ...214 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 225: ......
Страница 226: ...Part Number 24P2936 1P P N 24P2936...