Notes:
1.
If
a
diagnostics
panel
LED
is
lit
and
the
information
LED
panel
system-error
LED
is
off,
there
is
probably
an
LED
problem.
Run
LED
diagnostics.
2.
To
locate
the
LEDs
on
the
system
board,
see
“System-board
LED
locations”
on
page
47.
3.
Check
the
System
Error
Log
for
additional
information
before
replacing
a
FRU.
4.
The
DIMM
error
LEDs,
microprocessor
error
LEDs,
and
VRM
error
LEDs
turn
off
when
the
system
is
turned
off.
Note:
See
“System”
on
page
160
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Diagnostics
panel
LED
FRU/action
NMI
on
1.
If
PCI
x
LED
is
also
on,
follow
that
action.
2.
If
PCI
x
LED
is
not
on,
restart
the
server.
3.
Check
the
System
Error
Log.
ISMP
on
1.
Unplug
the
server
for
30
seconds,
and
then
retry.
2.
Reflash
or
update
firmware
for
ISMP,
BIOS.
3.
System
board.
LOG
on
1.
System
Error
Log
is
75%
full;
clear
the
log.
2.
PFA
alert;
check
log
for
failure;
clear
PFA
alert;
remove
ac
power
for
at
least
20
seconds,
reconnect,
then
turn
on
the
system.
3.
Run
light
path
diagnostics.
PCIA
on
1.
Check
System
Error
log.
2.
Remove
all
adapters
and
replace
one
at
a
time
until
failing
adapter
is
identified.
3.
System
board.
PCIB
on
1.
Check
System
Error
log.
2.
Remove
all
adapters
and
replace
one
at
a
time
until
failing
adapter
is
identified.
3.
System
board.
PCIC
on
1.
Check
System
Error
log.
2.
Remove
all
adapters
and
replace
one
at
a
time
until
failing
adapter
is
identified.
3.
System
board.
PCID
on
1.
Check
System
Error
log.
2.
Remove
all
adapters
and
replace
one
at
a
time
until
failing
adapter
is
identified.
3.
System
board.
DASD
on
(The
LED
located
next
to
the
drive
bay
that
the
failing
drive
is
installed
in
is
lit.
Check
the
amber
drive
LED
for
the
failing
hard
drive.)
1.
Be
sure
the
fans
are
operating
correctly
and
the
airflow
is
good.
2.
If
installed,
reseat
SCSI
cables
between
SCSI
backplane
and
the
system
board.
3.
Failing
hard
disk
drive.
4.
SCSI
backplane.
PS1
on
1.
Check
the
dc
good
LED
on
power
supply
1.
If
it
is
off,
replace
power
supply
1.
2.
Power
backplane.
Chapter
6.
Symptom-to-FRU
index
131
Содержание XSERIES 255 TYPE 8685
Страница 1: ...xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 2: ......
Страница 3: ...xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 6: ...iv xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 20: ...10 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 126: ...116 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 189: ...Appendix B Related service information 179...
Страница 190: ...180 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 191: ...Appendix B Related service information 181...
Страница 192: ...182 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 193: ...Appendix B Related service information 183...
Страница 194: ...184 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 195: ...Appendix B Related service information 185...
Страница 196: ...186 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 209: ...Appendix B Related service information 199...
Страница 210: ...200 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 211: ...Appendix B Related service information 201...
Страница 212: ...202 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 213: ...Appendix B Related service information 203...
Страница 214: ...204 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 224: ...214 xSeries 255 Type 8685 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 225: ......
Страница 226: ...Part Number 24P2936 1P P N 24P2936...