Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
Message
Severity
Description
Action
81070208-1881xxxx
Sensor MEU PS1 Therm has
transitioned to a less severe
state from critical
Info
MAX5 memory
expansion module
power supply 1 is
now normal.
No action;
information only.
80070208-1881xxxx
Sensor MEU PS1 Therm has
transitioned to critical from a
less severe state
Error
MAX5 memory
expansion module
power supply 1 error
detected.
1.
Check MAX5
memory
expansion
module LEDs.
2.
Check MAX5
memory
expansion
module power
supply 1 LEDs.
3.
Replace the
MAX5 memory
expansion
module power
supply 1.
80080004-1d06xxxx
Device MEU Fan 1 has been
removed from unit
[PhysicalPackageElementName]
Warning MEU Fan 1 is no
longer detected or is
not installed.
1.
Install the fan, if
missing.
2.
Reseat the fan
with the lit error
LED.
3.
Replace the fan if
the problem
remains.
4.
(Trained service
technician only)
Replace system
board.
80080004-1d07xxxx
Device MEU Fan 2 has been
removed from unit
[PhysicalPackageElementName]
Warning MEU Fan 2 is no
longer detected or is
not installed.
1.
Install the fan, if
missing.
2.
Reseat the fan
with the lit error
LED.
3.
Replace the fan if
the problem
remains.
4.
(Trained service
technician only)
Replace system
board.
Chapter 3. Diagnostics
241
Содержание System x3690 X5
Страница 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 13: ...Safety statements Safety xi...
Страница 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 407: ...1 2 Chapter 5 Removing and replacing components 389...
Страница 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 453: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices 435...
Страница 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 461: ...weight of memory enclosure 28 Index 443...
Страница 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 463: ......
Страница 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...