Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
Sensor Pwr Rail C Fault has
transitioned to non-recoverable.
Error
A sensor has
changed to
Nonrecoverable
state.
1.
Turn off the server and
disconnect it from
power.
2.
Remove the SAS/SATA
RAID riser card, the
DIMMs in connectors 1
through 8, and the
(Trained service
technician only)
microprocessor in socket
1.
3.
Reinstall each device,
one at a time, starting
the server each time to
isolate the failing
device.
4.
Replace the failing
device.
5.
(Trained service
technician only) Replace
the system board.
Sensor Pwr Rail D Fault has
transitioned to non-recoverable.
Error
A sensor has
changed to
Nonrecoverable
state.
1.
Turn off the server and
disconnect it from
power.
2.
(Trained service
technician only) Remove
the microprocessor from
socket 1.
3.
Reinstall the
microprocessor in socket
1 and restart the server.
4.
(Trained service
technician only) Replace
the failing
microprocessor.
5.
(Trained service
technician only) Replace
the system board.
Chapter 3. Diagnostics
183
Содержание System x3690 X5
Страница 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 13: ...Safety statements Safety xi...
Страница 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 407: ...1 2 Chapter 5 Removing and replacing components 389...
Страница 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 453: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices 435...
Страница 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 461: ...weight of memory enclosure 28 Index 443...
Страница 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 463: ......
Страница 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...